background image

-24-

© 2021 United States Stove Company

Glass “Soot’s” Up At A Very Fast Rate

Flame Is Lazy, Dark, And Has Black Tips 

After Stove Has Been On For A While, The Burnpot Overfills

Possible Causes

Possible Remedies: (Unplug stove first when possible)

Stove or vent pipe is dirty, which restricts 

airflow through the burnpot.

Follow all cleaning procedure in the maintenance section of 

the owner’s manual.

Vent pipe installed improperly.

Check to make sure the vent pipe has been installed 

according to the criteria in the owner’s manual.

Burnpot holes are blocked.

Remove the burnpot and thoroughly clean it.

Blockage in air intake pipe.

Visually  inspect  the  air  intake  pipe  that  leads  into  the 

burnpot for foreign material.

Combustion blower is not spinning fast 

enough.

Test  the  RPM  on  the  blower  after  the  blades  have  been 

cleaned. The RPM should be approximately 3000 RPM.

Bad  Pellets.  (Applies  to  GLASS  “SOOT’S”  UP 

AT A VERY FAST RATE Only)

The brand of pellets or the batch of pellets that are being 

used may be of poor quality. If possible, try a different brand 

of pellets. You might also want to try a brand that is made 

from  a  different  type  of  wood  (softwood  vs.  hardwood). 

Different woods have different characteristics when being 

burned.

TROUBLESHOOTING GUIDE

High Limit Switch Keeps Tripping

Possible Causes

Possible Remedies: (Unplug stove first when possible)

The convection blower is overheating and 

tripping the internal temperature shutoff.

Clean any dust off of the windings and fan blades. If oiling 

the blower does not help, the blower may be bad.

The stove is being left on the highest setting 

for extended periods of time.

If operating the heater on the highest heat setting, the room 

temperature could increase enough and lead to potential 

overheating  situations.  If  this  happens,  try  operating  at  a 

lower heat setting. 

Fuel other than wood pellets is being burned 

in the stove.

This pellet stove is designed and tested to use wood pellets. 

Check for signs of fuel other than wood pellets. No other 

types  of  fuel  have  been  approved  for  this  pellet  stove.  If 

there are signs of other types of fuel being used, stop using 

them immediately.

Power surge or brown out situation.

A power surge, spike, or voltage drop could cause the high 

limit switch to trip. Check to see if a surge protector is being 

used on the stove. If not, recommend one to the consumer.

High limit switch is malfunctioning.

If  the  other  items  check  out  okay,  replace  the  high  limit 

switch.

Summary of Contents for AP5710

Page 1: ...e officials about permits restrictions and installation requirements in your area NEVER OPERATE THIS PRODUCT WHILE UNATTENDED CAUTION Please read this entire manual before you install or use your new room heater Failure to follow instructions may result in property damage bodily injury or even death Improper Installation Will Void Your Warranty Save These Instructions In A Safe Place For Future Re...

Page 2: ...NSTOOPERATETHISWOODHEATERINAMANNERINCONSISTENT WITH THE OPERATING INSTRUCTIONS IN THE OWNER S MANUAL Heating Specifications Fuel Burn Rate lowest setting 1 5 lbs hr 0 7 kg hr Pellet size may effect the actual rate of fuel feed and burn times Fuel feed rates may vary by as much as 20 Use PFI listed fuel for best results Burn Time lowest setting 33 hrs approximate Hopper Capacity 50 lbs 22 7 kg Flue...

Page 3: ... Brand___________________________________ If no Date of inspection of existing venting system _______________________________________________________ COMMISSIONING Confirm Hearth Pad Installation as per Installation Instructions Confirm proper placement of internal parts Check soundness of door gasket and door seals Confirm clearances to combustibles as per installation instructions in this manual...

Page 4: ...lled wires out of the top of the stove There will be two wire harnesses as shown 2 Unpack the top mount controls and ensure that the wiring harness shown is attached securely 3 Connect the factory installed wiring harnesses to the control panel as shown 4 Secure the control panel to the top of the stove with two sheet metal screws ...

Page 5: ...R IS REQUIRED THIS UNIT MUST BE PLUGGED INTO A 110 120V 60 HZ GROUNDED ELECTRICAL OUTLET DO NOT USE AN ADAPTER PLUG OR SEVER THE GROUNDING PLUG DO NOT ROUTE THE ELECTRICAL CORD UNDERNEATH IN FRONT OF OR OVER THE HEATER DO NOT ROUTE THE CORD IN FOOT TRAFFIC AREAS OR PINCH THE CORD UNDER FURNITURE CAUTION BURNING FUEL CREATES CARBON MONOXIDE AND CAN BE HAZARDOUS TO YOUR HEALTH IF NOT PROPERLY VENTED...

Page 6: ...ith CAN ULC standards Needs to extend 18 to the front 8 beyond each side of the unit A Back to Stove U S A 1 26 mm CAN 8 204 mm B Side to Stove U S A 6 153 mm CAN 8 204 mm C Front to Stove U S A 6 153 mm CAN 8 204 mm D Back to Flue 2 51 mm CLEARANCES Your pellet stove has been tested and listed for installationinresidential mobilehomeinaccordance with the clearances given below For safety reasons ...

Page 7: ...tar washer to penetrate paint or protective coating to ensure grounding Vent must be 3 or 4 inch PL Vent and must extend a minimum or 36 914 mm above the roof line of the mobile home and must be installed using a certified ceiling fire stop and rain cap When moving your mobile home all exterior venting must be removed while the mobile home is being relocated After relocation all venting must be re...

Page 8: ...ipe is not furnished with the unit and must be purchased separately PELLET VENT INSTALLATION The installation must include a clean out tee to enable collection of fly ash and to permit periodic cleaning of the exhaust system 90 degree elbows accumulate fly ash and soot thereby reducing exhaust flow and performance of the stove Each elbow or tee reduces draft potential by 30 to 50 All joints in the...

Page 9: ...or one every 4ft 1 22m to make the system more stable If you live in an area that has heavy snowfall it is recommended that the installation be taller than 3ft 0 91m to get above the snowdrift line This same installation can be used if your heater is below ground level by simply adding the clean out section and vertical pipe inside until ground level is reached With this installation you have to b...

Page 10: ... the two digit display indicate the mode of operation Manual or T Stat The stove has to be in normal operation to be switched from Manual to T Stat mode Manual mode operates according to the 5 set levels of feed on the bar graph from heat range 1 to heat range 5 T Stat mode works as follows The stove has a built in Thermostat into the controls of the appliance The temperature sensor for the T Stat...

Page 11: ...ELLET FUEL INSTITUTE PFI Your pellet stove is designed to burn premium hardwood pellets that comply with the Pellet Fuels Institute PFI standard minimum of 40 lbs density per cubic ft 1 4 to 5 16 diameter length no greater than 1 5 not less than 8 200 BTU lb moisture under 8 by weight ash under 1 by weight and salt under 300 parts per million Pellets that are soft contain excessive amounts of loos...

Page 12: ...ring this period because the paint could be affected Attempts to achieve heat output rates that exceed heater design specifications can result in permanent damage to the heater AUTOMATIC IGNITOR Fill hopper and clean burn pot 1 Press On Off button Make sure green light comes on 2 Adjust feed rate to desired setting by pressing Heat Level Advance button If fire doesn t start in 12 minutes press On ...

Page 13: ...temperature thermodisc This unit has a manual reset thermodisc This safety switch has two functions A To recognize an overheat situation in the stove and shut down the fuel feed or auger system B Incaseofamalfunctioningconvectionblower the high temperature thermodisc will automatically shut down the auger preventing the stove from overheating NOTE On some units once tripped like a circuit breaker ...

Page 14: ...he heat exchanger To access these clean outs you must remove both side panels The clean outs are secured to the firebox with 2 5 16 screws Remove the clean outs and vacuum out any accumulated ash This should be done at least once per month or more frequently if large amounts of ash are noticed while cleaning or if the stove does not seem to be burning properly If a vacuum is used to clean your sto...

Page 15: ...cleaned and if necessary repaired To clean the chimney disconnect the vent from the stove FLY ASH This accumulates in the horizontal portion of an exhaust run Though non combustible it may impede the normal exhaust flow It should therefore be periodically removed ASH REMOVAL DISPOSAL CAUTION ALLOWTHESTOVETOCOOLBEFOREPERFORMING ANY MAINTENANCE OR CLEANING ASHES MUST BE DISPOSED IN A METAL CONTAINER...

Page 16: ...t attempt to operate the unit with broken glass Replacement glass may be purchased from your U S Stove dealer If glass is broken follow these removal procedures 1 Remove the four 4 screws and glass retainers 2 While wearing leather gloves or any other gloves suitable for handling broken glass carefully remove any loose pieces of glass from the door frame Dispose of all broken glass properly ONLY h...

Page 17: ...sstove com The information in this owner s manual is specific to your unit When ordering replacement parts the information in this manual will help to ensure the correct items are ordered Before contacting customer service write down the model number and the serial number of this unit That information can be found on the certification label attached to the back of the unit Other information that m...

Page 18: ...lide about 1 4 after your stove cools down Restart your stove If your display shows E1 again close the slide another 1 4 and restart The convection blower is overheating and tripping the internal temperature shutoff Clean any dust off of the windings and fan blade If oiling the blower does not help the blower may be bad The stove is being left on the highest setting for extended periods of time If...

Page 19: ... Combustion blower failure With the stove on check to see if the combustion blower is running If it is not you will need to check for power going to the combustion blower It should be a full current If there is power the blower is bad If there is not make sure the control board is sending power to the air switch Control board not sending power to combustion blower If there is no current going to t...

Page 20: ...emove the two bolts that hold the auger bracket to the auger tube The auger bracket will now be able to be removed form the auger tube Remove the two bolts on the side of the auger tube to remove the lower bearing of the auger Pull the auger out of the tube to free the jam The auger motor has failed Remove the auger motor from the auger shaft and try to run the unit If the motor will turn the shaf...

Page 21: ...erating the unit be sure the hopper lid is closed so that the hopper safety switch will activate Check the wires leading from the hopper safety switch to the control panel and auger motor for secure connections Use a continuity tester to test the hopper safety switch replace if necessary The auger shaft is jammed Start by emptying the hopper Then remove the auger motor by removing the auger pin Re...

Page 22: ...o The Home Possible Causes Possible Remedies Unplug stove first when possible There is a leak in the vent pipe system Inspect all vent pipe connections Make sure they are sealed with RTV silicone that has a temperature rating on 500 degree F or higher Also seal joints with UL 181 AP foil tape Also make sure the square to round adapter piece on the combustion blower has been properly sealed with th...

Page 23: ... shaft inspection plate in the hopper so that you can see the auger shaft Gently lift the auger shaft straight up so that the end of the auger shaft comes up out of the bottom auger bushing Next remove the two nuts that hold the top auger biscuit in Then rotate the bottom end of the auger shaft up towards you until you can lift the shaft out of the stove After you have removed the shaft inspect it...

Page 24: ...rent type of wood softwood vs hardwood Different woods have different characteristics when being burned TROUBLESHOOTING GUIDE High Limit Switch Keeps Tripping Possible Causes Possible Remedies Unplug stove first when possible The convection blower is overheating and tripping the internal temperature shutoff Clean any dust off of the windings and fan blades If oiling the blower does not help the bl...

Page 25: ...199 Housing PCBA Controller 1 7 80491 Microswitch 1 8 80709 Room Blower 1 9 88347 T Disc Room Air Gasket 2 10 80601 T Disc Room Air 1 11 80599 T Disc Exhaust 1 12 80602 Exhaust Blower 1 13 80488 Drive Motor 1 5 RPM CCW 1 14 88166 Gasket Exhaust Blower 1 15 80549 Vacuum Switch 1 16 80869 Ceramic Ignitor 1 17 88118 Ignitor Flange Gasket 1 IN ORDER TO MAINTAIN WARRANTY COMPONENTS MUST BE REPLACED USI...

Page 26: ... 26 2021 United States Stove Company 1 25A 250V FUSE 7 5A 250V FUSE CORRECT WRONG Ensure the wires are connected to the bottom two prongs of the hopper switch as shown WIRING DIAGRAM ...

Page 27: ... 27 2021 United States Stove Company NOTES ...

Page 28: ..._______ Engineer Name _____________________________________ License No _________________________________________ Company ___________________________________________ Telephone No ______________________________________ Stove Inspected Chimney Swept Items Replaced _____________________________________ Service 02 Date _______________________ Engineer Name _____________________________________ License ...

Page 29: ...vice fiable et efficace de votre appareil de chauffage et vous permettre de commander correctement les pièces de rechange Conservez ce manuel dans un endroit sûr pour référence future Lors de l écriture toujours donner le numéro de modèle complet qui se trouve sur la plaque signalétique fixée sur l appareil de chauffage Lors de la commande des pièces de rechange fournir les informations suivantes ...

Page 30: ...26 ...

Page 31: ...25 1 25A 250V Fusible 7 5A 250V Fusible Schéma de câblage CORRECT FAUX Assurez vous que les fils sont connectés aux deux broches inférieures de l interrupteur de la trémie comme illustré ...

Page 32: ...ent 1 20 80529 Moteur De Vis Sans Fin 1 21 892665 Support De Montage Du Moteur De La Vis Sans Fin 1 22 892661 Soudure Du Boîtier De La Tarière 1 23 892677 Tarière 1 24 892664 Douille D agitateur 1 25 80455 Disque En T Pour Air Ambiant 1 26 80709 Ventilateur De Pièce 1 27 80549 Interrupteur À Vide 1 28 88176 Couverture Isolante 1 29 892659 Soudure Principale 1 30 892671 Bas Avant 1 31 892670 Assemb...

Page 33: ...23 Schéma des pièces 3 1 6 7 8 9 10 11 12 13 14 15 16 17 18 29 30 31 28 27 26 25 23 24 5 22 21 20 4 19 2 ...

Page 34: ... utilisés est peut être de mauvaise qualité Si possible essayez une autre marque de granulés Essayez aussi une marque composée d un autre type de bois résineux plutôt que feuillus Des bois différents présentent des caractéristiques différentes qui affectent la combustion Guide de dépannage L interrupteur de surchauffe se déclenche tout le temps Causes possibles Solutions possibles Débranchez le po...

Page 35: ...rière et essayez de le faire fonctionner Si le moteur tourne c est l arbre qui est coincé sur quelque chose Si le moteur ne tourne pas il est défectueux Tarière bloquée Commencez par vider la trémie Puis retirez le moteur de la tarière en retirant la goupille de la tarière Retirez la plaque d inspection de l arbre de la tarière dans la trémie pour pouvoir examiner l arbre de la tarière Soulevez lé...

Page 36: ...ande n envoie pas de courant à l allumeur Vérifiez la tension qui arrive à l allumeur lors du démarrage Ce doit être la tension nominale Si la tension est inférieure à la valeur nominale vérifiez le câblage Si le câblage est bon c est le tableau qui est défectueux UNE ODEUR DE FUMÉE EST REFOULÉE DANS LA PIÈCE Causes possibles Solutions possibles Débranchez le poêle avant toute chose quand c est po...

Page 37: ...teur de continuité pour tester l interrupteur de sécurité de la trémie remplacer le si nécessaire L arbre de la tarière est coincé Commencez par vider la trémie Puis retirez le moteur de la tarière en retirant la goupille de la tarière Retirez la plaque d inspection de l arbre de la tarière dans la trémie pour pouvoir examiner l arbre de la tarière Soulevez légèrement l arbre de la tarière de sort...

Page 38: ...ite le moteur de la tarière en retirant la goupille de la tarière puis retirez les deux boulons qui fixent le support de tarière au tube de tarière Vous pouvez maintenant retirer le support du tube de tarière Retirez les deux boulons du côté du tube de tarière pour déposer le roulement inférieur de la tarière Tirez sur la tarière pour la sortir du tube afin de lever le blocage Le moteur de la tari...

Page 39: ...lateur de combustion Lorsque le poêle est en marche vérifiez si le ventilateur de combustion est en fonctionnement Sinon vérifiez l alimentation électrique du ventilateur de combustion Ce doit être la tension nominale Si l alimentation électrique est bonne c est le ventilateur qui est défectueux Si l alimentation est absente reportez vous au point No 8 Le tableau de commande n envoie pas le couran...

Page 40: ...ffe et déclenche l arrêt de température interne Enlevez la poussière des bobinages et pales de ventilateur Si le graissage du ventilateur ne suffit pas il se peut que le ventilateur soit défectueux Le poêle est demeuré sur le réglage le plus élevé pendant de longues périodes En cas d utilisation du poêle sur le réglage de chauffage le plus élevé il se peut que la température de la pièce s élève au...

Page 41: ...si le bon moment pour nettoyer à fond la totalité du poêle ARRÊT AU PRINTEMPS Après la dernière flambée du printemps retirez tous les granulés restants de la trémie et du système d alimentation à tarière Enlevez tout d abord les granulés avec une pelle puis faites fonctionner la tarière jusqu à ce que la trémie soit vide et que les granulés cessent de couler il suffit pour cela d appuyer sur l inte...

Page 42: ...et nettoyez ses pales dans le cadre des opérations de mise en marche en automne MONITEURS DE FUMÉE ET DE CO La combustion du bois produit naturellement le monoxyde de carbone CO et de la fumée CO est un gaz toxique lorsqu il est exposé à des concentrations élevées pendant des périodes de temps prolongées Alors que les systèmes de combustion modernes réchauffeurs réduisent considérablement la quant...

Page 43: ...gards de nettoyage sont situés à l intérieur des portes d armoires sur les coins avant inférieurs de l échangeur de chaleur Pour accéder à ces outs propres vous devez retirer les deux panneaux latéraux Les sorties propres sont fixées à la chambre de combustion avec 2 vis 5 16 po Retirez les feuilles propres et aspirer les cendres accumulées Cela devrait être fait au moins une fois par mois ou plus...

Page 44: ...é les poêles à granulés peuvent accumuler de la créosote dans certaines conditions Cendres volantes Elles s accumulent dans la portion horizontale du conduit d évacuation Bien qu elles ne soient pas combustibles elles peuvent gêner le flux normal d évacuation Elles doivent donc être périodiquement éliminées Inspection et élimination Le raccord et le conduit de cheminée doivent être inspectés par un...

Page 45: ...s de l écran s éteignent et l écran à deux chiffres affiche E3 en clignotant RECHARGE EN COMBUSTIBLE La trémie et le couvercle du poêle sont chauds pendant le fonctionnement vous devez toujours protéger vos mains lors du remplissage du poêle Ne placez jamais la main près de la tarière pendant le fonctionnement du poêle Nous recommandons de ne pas laisser la trémie se vider à moins du quart de sa c...

Page 46: ...nulés Évitez les marques de granulés qui présentent les caractéristiques suivantes 1 Un excès de fines Le terme fines décrit les granulés écrasés ou les matériaux libres qui ressemblent à de la sciure ou à du sable Il est possible de tamiser les granulés avant de les placer dans la trémie pour éliminer la plupart des fines 2 Des liants Certains granulés sont produits avec des matériaux liants qui ...

Page 47: ...age de chaleur pour laquelle il était réglé avant de passer en mode T stat si le poêle était réglé sur le niveau de chauffage 5 avant de passer en mode T stat il revient à niveau de chauffage 5 lorsqu il atteint la plage de 3 F autour du point de consigne Lorsque le poêle atteint le point de consigne souhaité il passe au niveau de chauffage 1 Lorsque la température ambiante passe sous le point de ...

Page 48: ...haleur mais les conditions de fonctionnement du poêle ne changent pas avant la fin de la période de démarrage Pendant la période de démarrage le feu doit démarrer en 12 minutes sinon le poêle passe en mode d erreur et affiche le code E4 Pendant la phase de démarrage la touche Mode n est pas fonctionnelle B TOUCHES FLÉCHÉES DE NIVEAU TEMPÉRATURE Ces touches permettent de régler le débit d alimentat...

Page 49: ...u tuyau d entrée d air à l arrière du poêle comme illustré 8 Étirez le tuyau flexible de 2 po à l entrée d air à l arrière du poêle Fixez en utilisant l autre collier de serrage de 2 po Le tuyau s étendra jusqu à 4 pieds de longueur SORTIE D ÉCHAPPEMENT ENTRÉE D AIR FRAIS Figure 1 B C E A Figure 2 A D CONDITIONS SPECIALES D INSTALLATION DANS UNE MAISON MOBILE Avertissement N installez pas l apparei...

Page 50: ... alcôve sous une fenêtre ou entre deux fenêtres Nous recommandons les kits Simpson Dura Vent ou Metal Fab INSTALLATION PAR LE TOIT LE PLAFOND En cas d évacuation des fumées du poêle par le plafond le tuyau est raccordé comme pour l évacuation par le mur mais le T de nettoyage est toujours à l intérieur de la maison et un adaptateur de 3 po 76 mm est ajouté avant le T de nettoyage Vous devez toujou...

Page 51: ...tème d évacuation pour poêle à granulés de type PL de 3 ou 4 po 76 à 102 mm homologué UL et fixez le au raccord de tube installé à l arrière du poêle utilisez un adaptateur de 3 ou 4 po pour un tuyau de 4 po Le raccord à l arrière du poêle doit être étanchéifié avec du RTV haute température composé de caoutchouc de silicone résistant aux variations de température Utiliser une évacuation de 4 po si...

Page 52: ...tielle et mobile conformément aux dégagements indiqués ci dessous Pour des raisons de sécurité veuillez respecter les dégagements et restrictions d installation Toute réduction du jeu aux combustibles ne peut être effectuée que par des moyens approuvés par une autorité réglementaire po mm A Mur latéral au poêle 10 254 B Mur latéral au tuyau de ventilation 11 5 292 C Mur arrière au poêle 11 875 302...

Page 53: ... 200 Btu lb humidité inférieure à 8 en poids de cendre de moins de 1 en poids et le sel à moins de 300 parties par million Pellets qui sont doux contenir des quantités excessives de la sciure de bois en vrac ont été ou sont mouillés se traduira par une réduction des performances Stockez vos pellets dans un endroit sec NE PAS entreposer le carburant dans les autorisations d installation de l unité ...

Page 54: ... fonctionner le poêle lorsque la porte d observation est ouverte Dans ce cas la tarière ne distribue pas les granulés et un problème de sécurité peut se poser en raison des étincelles ou des fumées pénétrant dans la pièce Laissez le poêle refroidir avant d effectuer tout entretien ou nettoyage Les cendres doivent être évacuées dans un récipient métallique doté d un couvercle hermétique Le récipien...

Page 55: ...CHANGE CONSERVER DANS UN ENDROIT SÛR POUR RÉFÉRENCE FUTURE Certifié pour ASTM E1509 12 2017 et Certifié pour ULC S627 00 Rapport F19 549 Cet appareil n a pas été conçu pour être utilisé en tant que source principale de chaleur US Environmental Protection Agency Certifié conforme aux normes d émissions de 2020 à particules AVERTISSEMENT CONCERNANT LA PROPOSITION 65 DE L ÉTAT DE LA CALIFORNIE Ce pro...

Reviews: