ASG DTT Series Operating Manual Download Page 1

 
 
 
 
 
 
 

 

 

 

DTT OPERATING MANUAL 

 

 

 

 

SEPTEMBER 2013 DTT Version 4H  

 
 

ASG Div. Jergens Inc

15700 S. Waterloo Rd.  

Cleveland Ohio 44110-3898 

Phone: 216-486-6163 

Fax: 216-481-4519 

  

E-mail: 

Web: www.asg-jergens.com 

 

 
 

 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for DTT Series

Page 1: ...OPERATING MANUAL SEPTEMBER 2013 DTT Version 4H ASG Div Jergens Inc 15700 S Waterloo Rd Cleveland Ohio 44110 3898 Phone 216 486 6163 Fax 216 481 4519 E mail asginfo asg jergens com Web www asg jergens...

Page 2: ...ion 9 Printing and Data output 9 Service and Warranty 9 System Overview 10 Torque Conversion Factors 11 NOTE The Programming and Calibration Manual contains the password to enter the calibration menu...

Page 3: ...r after installation 2 STANDARD EQUIPMENT All DTT meters are supplied with the following standard items Plastic carrying case RS 232 Communication cable or USB to Serial bridge cable CD containing ASG...

Page 4: ...nit will default to the PEAK setting when turned on Use the MODE button to change to the TRACK or FIRST PEAK setting if desired This function may not work with the battery charger connected to the uni...

Page 5: ...on you will only change the mode Button 4 MEM Memory In normal operation pressing the MEM button enters the torque reading into the DTT memory 5 OVERLOAD CAPACITY CAUTION Do not deliberately exceed th...

Page 6: ...e RESET ESC button to be sure the display is at 0Run the tool forward until it shuts off The reading on the display will be the torque setting of the tool s clutch Note the reading or write it down To...

Page 7: ...ecome unscrewed or disassembled during use Refer to the drawing below for proper assembly rather then relying on the creativity of individuals All ASG DTT driver adapters using springs regardless of t...

Page 8: ...612 1 3 to 5 lbf in 66616 Replacement Black Spring for 66612 4 3 to 26 lbf in 66618 Replacement Driver Adapter hex drive 25 to 90 lbf in New one piece unit replaces earlier 2 piece unit 66634 Replacem...

Page 9: ...t printing to a serial printer Either the PS2 to DB9 or the USB to Serial bridge cable can be used To print see the instructions in the Programming and Calibration manual in the AUTO PRINT section of...

Page 10: ...hargeable Battery charger 110 120 VAC 60 Hz 12W input 12 VDC 500mA output Optional 220 240 VAC input available ADC 24 bits CPU 8 bits Communication RS232C Key button 4 Buttons Unit of measure 9 User S...

Page 11: ...1 152 0 0115 113 0 11 3 0 113 1 lbf ft 192 0 12 0 1 0 13826 0 13 83 0 138 1356 0 135 6 1 356 1 gf cm 0 014 0 0009 0 00007 1 0 0 001 0 0001 0 098 0 01 0 0001 1 kgf cm 13 890 0 868 0 072 1000 0 1 0 0 0...

Page 12: ...12 Division of Jergens Inc 15700 S Waterloo Road Cleveland Ohio 44110 3898 Toll Free 888 486 6163 Fax 216 481 4519 Email asginfo asg jergens com www asg jergens com...