SECTION 3 –
Installation and connection
Figure 20
Installation distances
3.5
Checking installation distances
To ensure adequate ventilation it is necessary leaving the following open spaces
around the system:
X
direction 15 mm (min.) for each side.
Y
direction 50 mm (min.) for each side.
Z
direction 10 mm (min.).
3.6
Preparing the mounting cut-out
In order to ensure a proper mounting of the system, the material of the mounting
cut-out must be sufficiently stable.
To obtain the degree of protection described below, the material of the mounting
panel must not deform due to the use of clamps on the operator panel.
X
X
Y
Y
Z