AsconPool MS3D-UD Installations Download Page 1

MS3D-UD

MULTI SOLAR 

CONTROLLER

UP-DOWN

Summary of Contents for MS3D-UD

Page 1: ...MS3D UD MULTI SOLAR CONTROLLER UP DOWN...

Page 2: ...INSTALLATION INCLUDED Solar Controller Down pipe Sensor Up pipe Sensor Mounting kit and template...

Page 3: ...INSTALLATION REQUIRED 6mm Masonry drill bit required for raw plugs P 2 Phillips head screw Driver Drill with hammer action or 12 5mm Drill bit Or cutting Tool ms Drill...

Page 4: ...TALLATION DO S 3 5m Unit must be 3 5m from pool zone Less than 1 5m from the pump 1 5m Unit must be installed in the upright position 1 metre from the ground 1m Unit must be mounted using screws provi...

Page 5: ...INSTALLATION DO NOT S Do not immerse Do not place unit upside down Do not place within direct splashing or spray from the pool...

Page 6: ...INSTALLATION UP PIPE SENSOR Using the 12 5mm drill bit drill a hole into the up pipe Plug sensor cable into the unit using the red connectors Put the grommet in first then push in the up pipe sensor...

Page 7: ...NSTALLATION DOWN PIPE SENSOR Using the 12 5mm drill bit drill a hole into the down pipe Put the grommet in first then push in the down pipe sensor Attach the cables to the unit using the red connector...

Page 8: ...Plug controller piggy back into GPO if a stand alone system Plug the solar pump into the base of solar controller INSTALLATION For a stand alone system...

Page 9: ...an integrated system Plug the chlorinator into the power point Plug the solar controller grey piggy back into the chlorinator Plug the filter pump into the grey piggy back Plug the solar pump into the...

Page 10: ...After 2 mins the unit will run for at least 6 mins to reset the down pipe sensor When the unit is turned on there will be a period of 2 mins while the MS3D UD and the solar pump synchronise indicated...

Page 11: ...ERATION CLOCK SET UP When the unit is turned on the set time LED will be flashing Set the time using the for the hours and the for the minutes The clock will need to be set after the unit is powered u...

Page 12: ...ximum 40 C by 1 C increments Press button to decrease to minimum 20 C by 1 C increments When the comfort temperature is set this temperature will be stored even when the unit is turned off The comfort...

Page 13: ...is the difference in the temperature between the up pipe and the down pipe Press the and buttons at the same time The unit will show on the display The current differential is displayed To change the...

Page 14: ...next day The default time is 4pm Unit operates in 24 hour time Press the button and the button at the same time The unit will display Use the button the adjust the hours and the button to adjust the m...

Page 15: ...display mode allows the user to check each mode setting without accessing or changing the current settings The unit will cycle through the settings showing U For the up pipe temp C For the comfort se...

Page 16: ...the end of the season press for winter mode At the start of the season press for normal operation Winter mode allows the users solar system to function during cooler months This extends the life of t...

Page 17: ...erride On To select a 4 hour override on press and hold the and at the same time for 5 seconds What does override do To select a 1 hour override Press and at the same time Press both buttons again to...

Page 18: ...OPERATION CALIBRATION Press and to calibrate the pool sensor Display reads CAL then 00 To calibrate the unit Press the or to offset the temperature...

Page 19: ...TROUBLE SHOOTING GUIDE...

Page 20: ...For further information please refer to the Installation Guide and Instruction Manual www asconpool com au...