background image

Temperature 
Controller

1

/

16

DIN - 48 x 48 

M1 line 

c

c

U s e r   m a n u a l   •   M . I . U . M 1 - 5 / 0 9 . 0 5   •   C o d .   J 3 0 - 4 7 8 - 1 A M 1   I E

M1UK.ed5  14-05-2009  14:56  Pagina 1

ISO 9001

C e r t i f i e d

Ascon Tecnologic srl
via Indipendenza 56, 
27029 Vigevano (PV)
Tel.: +39-0381 69 871
Fax: +39-0381 69 8730
Internet site: 

www.ascontecnologic.com

E-Mail address: 

[email protected]

Summary of Contents for M1 line

Page 1: ...M1 5 09 05 Cod J30 478 1AM1 IE M1UK ed5 14 05 2009 14 56 Pagina 1 ISO 9001 C e r t i f i e d Ascon Tecnologic srl via Indipendenza 56 27029 Vigevano PV Tel 39 0381 69 871 Fax 39 0381 69 8730 Internet...

Page 2: ...Temperature Controller 1 16 DIN 48 x 48 M1 line c c 1 2 AT M1UK ed5 14 05 2009 14 56 Pagina 1...

Page 3: ...ity directive no 92 31 EEC 93 68 EEC 98 13 EEC and the following regulations Regulations on RF emissions EN61000 6 3 2001 residential environments EN61000 6 4 2001 industrial environments Regulation o...

Page 4: ...Page 29 Main universal input Control Alarms Retransmission Resources OP1 PV OP2 OP4 option Setpoint Operating mode PV M1 1 Single OP1 OP2 OP4 action 2 Single OP2 OP1 OP4 action 0 Indication OP1 OP2 O...

Page 5: ...bol related to the European Community directive on electrical protection and electromagnetic compatibility B To prevent hands or metal touch ing parts that may be electrically live the controllers mus...

Page 6: ...NSIONAL DETAILS 48 mm 1 89 in 120 mm 4 72 in 48 mm 1 89 in 20 mm max 0 79 in max 1 3 PANEL CUT OUT 65 mm min 2 56 in min 45 0 6 mm 1 78 0 023 in 45 0 6 mm 1 78 0 023 in 65 mm min 2 56 in min M1UK ed5...

Page 7: ...ir ventilation Use 24Vac supply version Suggestions Forbidden Conditions D C Corrosive atmosphere E Explosive atmosphere Operating conditions M Altitude up to 2000 m T Temperature 0 50 C 1 Rh Relative...

Page 8: ...instrument 1 3 2 1 5 3 CLAMPS REMOVING 1 Insert the screwdriver in the clips of the clamps 2 Rotate the screwdriver 1 2 1 5 4 INSTRUMENT UNPLUGGING B 1 Push and 2 pull to remove the instrument Electr...

Page 9: ...cover Wire size 1 mm2 18 AWG Solid Stranded 2 5 7 mm 0 22 in 14 screw terminals Option terminals Tightening torque 0 5 Nm Pillips screwdriver PH1 Flat blade screwdriver 0 8 x 4 mm 1 TC mA mV OP1 2 3...

Page 10: ...gh power motors nearby Avoid power units nearby espe cially if controlled in phase angle Keep the low level sensor input wires away from the power lines and the output cables If this is not achievable...

Page 11: ...ons have been completed 3 In accordance with the safety reg ulations the power supply switch shall bring the identification of the relevant instrument The power supply switch shall be easily accessibl...

Page 12: ...e load of up to 2A 250Vac 4A 120Vac max Fuse 2AT 250Vac 4AT 120Vac IEC 127 B Triac Output NO contact for resistive load of up to 1A 250Vac max Fuse 1A T IEC 127 B Single relay output NO contact for re...

Page 13: ...pliance to the EIA RS485 standard for Modbus Jbus A Please read gammadue and deltadue controller series serial com munication and configuration RX TX 7 8 Load 7 8 mA OP2 OUTPUT B OP2 output can be rel...

Page 14: ...When the distance between the controller and the sensor is 15 m using a cable of 1 5 mm2 size produces an error on the measure of 1 C For L J K S T thermocouple type Wire resistance 150 max ForPT100r...

Page 15: ...coding are accessible from the front panel by mean of a particular procedure described at section 4 2 2 page 19 L C D M N B P N CONF S N V L N M1 3000 0000 2002 A0A 9809 0013 85 264V 50 60 Hz 2 6W 30...

Page 16: ...Spanish English 3 Front panel colour G Dark std 0 Beige 1 OP1 Output B Relay 0 Triac 3 Power supply A 100 240Vac 15 10 3 24Vac 25 12 or 24Vdc 15 25 5 Line 1 M 3 1 MODEL CODE The product code indicate...

Page 17: ...ar 8 Custom input and range TR Pt100 IEC751 1 9 TC L Fe Const DIN43710 2 328 752 F TC J Fe Cu45 Ni IEC584 3 32 2192 F 32 2912 F 99 9 572 9 F 328 1112 F 32 1112 F 32 1112 F 200 400 C 0 1200 C 0 1600 C...

Page 18: ...nfiguration code is set correctly see chapter 4 6 pag 26 Conf 1 2 AT Alarm 2 type and function N Not active 0 Sensor break alarm 1 Absolute 2 active high 3 active low Deviation 1 active high 4 active...

Page 19: ...in engineering units when the measured value is greater than sensor high range when the measured value is less than the sensor low range Code and or value of the Parameter programming mode 1 2 AT Dev...

Page 20: ...l operating conditions 4 2 1 OF THE PROCESS VARIABLES 4 2 2 OF THE CONFIGURATION CODES 274 8 Unit s p Out 270 5 63 0 C Operator mode Engineering units 1 Setpoint Control output 2 Note 1 See page 27 2...

Page 21: ...stops when it has reached the max min limit set for the parame ter 4 3 1 NUMERIC ENTRY i e the modification of the value of a stored Setpoint from 275 0 to 240 0 4 3 2 MNEMONIC CODES SETTING e g conf...

Page 22: ...keypad lock unlock can be achieved by serial communications too AThe keypad lock is main tained in case of power failure 4 4 2 OUTPUTS LOCK The outputs are switched to the OFF status by pressing the...

Page 23: ...PASS 5000 A1s p Back to the Operator mode 1st GROUP AL1 alarm threshold 1 see pag 24 AL2 alarm threshold 2 see pag 24 Proportional band PID algorithm only 0 5 999 9 of span Integral time PID algorith...

Page 24: ...999 9 digit min Setpoint ramp down not available with 2 alarms 0ff 0 1 999 9 digit min Setpoint low limit not available with 2 alarms low range s p H Setpoint high limit not available with 2 alarms s...

Page 25: ...It is the derivative term coefficient that specifies the time required by the pro portional term P to reach the level of D When Off the derivative term is not included in the control algorithm Contro...

Page 26: ...ysteresis AL2 alarm hysteresis Hysteresis of the threshold of both the alarms that activate OP1 and OP2 control output It is specified as a of the full scale Input filter time constant Time constant i...

Page 27: ...AT Values modification Modification Selection enter Parameter menu selection OK 274 8 PASS 5000 AIs p sc lo prot sc Hi retr baud Code CONFIGURATION MENU 1st GROUP Operator mode Low range 2 linear scal...

Page 28: ...Conf Unit sc d d 2002 I L M N 33 2nd GROUP Engineering units see table No of decimals linear scale only 0 3 Entry of digits I L M N of the configuration code chapter 3 2 page 16 Code entry 0 4999 33 d...

Page 29: ...t of the autotune operation the PV is far from the Setpoint of more than 5 of the span This method has the big advantage of fast calculation with a reasonable accuracy in the term calculation Natural...

Page 30: ...conds Sampling time 0 5 seconds Input bias 60 60 digit Input filter with enable disable 1 30 seconds Accuracy 0 25 1 digits for temperature sensors 0 1 1 digits for mV and mA Between 100 240Vac the er...

Page 31: ...OFF Hysteresis 0 1 10 0 c s Proportional band P 0 5 999 9 Integral time I 0 1 100 0 min OFF O Derivative time D 0 01 10 00 min Cycle time 1 200 s Overshoot control 0 01 1 00 High limit 100 0 10 0 Hys...

Page 32: ...magnetic compatibility Access protection Power supply Protection EN650529 Compliance to the CE standards for industrial system and equipment Electric safety IP20 terminal block IP65 front panel 18Vdc...

Page 33: ...ant that the products will be free from defects in material and workmanship for 18 months from the date of delivery The warranty above shall not apply for any failure caused by the use of the product...

Page 34: ...33 M1UK ed5 14 05 2009 14 56 Pagina 33...

Page 35: ...lock Current transformer Outputs lock mA Remote setpoint Start up function Volt Remote setpoint Timer function Feedback potentiometer Memorized Remote Setpoint programmer SSR drive mA mV mA SPDT Relay...

Reviews: