ube

WINE
CONTROLLER
78 x 35 mm

Model KR1E

22/03 - Code: ISTR_Q_KR1E_E_06_--

DECLARATION OF CONFORMITY AND 
MANUAL RETRIEVAL

KR1E is a panel mounting, Class II instrument designed to comply 
with European directives.  All information about the controller use 
can be found in the “Engineering Manual”.
The Declaration of Conformity and the manual of the controller 
can be downloaded (free of charge) from the web-site:

www.ascontecnologic.com

Once connected to the web-site, search: 

KR1E

then click on 

KR1E

.

In the lower part of the product page (in any language) is present 
the download area with links to the documents available for the 
controller (in the available languages).

 

Warning

!

- Whenever a failure or a malfunction of the device may cause 

dangerous situations for persons, things or animals, please 
remember that the plant must be equipped with additional 
devices which will guarantee safety.

- We warrant that the products will be free from defects in material and 

workmanship for 18 months from the date of delivery.  Products 
and components that are subject to wear due to conditions of 
use, service life and misuse are not covered by this warranty.

Disposal

The appliance (or the product) must be disposed 

of separately in compliance with the local 

standards in force on waste disposal.

KR1E

PV

AT

Access to:

-  Operator Commands

-  Parameters

-  Configuration

Access to:

- Operator additional information

-  Set Point

Increase the displayed 

value/Selects the para-

meters list next element
Decrease the displayed 

value or select the 

previous element
Exit from Operator 

commands/Parameter 

setting/Configuration

Programmable key:

Start the programmed function 

(Autotune, Auto/Man, Timer ...)

Access to:

-  Set Point

Operator Mode

Editing Mode

Confirm and go to 

Next parameter

These 2 keys, pressed in sequence, allow to toggle 
between MANual and AUTO modes.

+

Process Value

(in eng. units)

Output LEDs

Manual mode

Alarm active

Unit (°C/°F)

Autotune in progress 

(flashing)

DISPLAY AND KEYS

Set Point 

(auto mode)

Output Value 

(manual mode)

Parameter value

 or 

State/

Function selected 

(editing mode)

MODEL CODE

The Hardware resources are identified by the following Model Code.

KR1E

A B C D E F G H

Model:

Supply voltage:  100... 240 Vac/

18...  28 Vac/

20... 30 Vdc

ELECTRICAL CONNECTIONS

RS485

DI1

OP3

OP2

NO

NO

C

C

C

NO

NF

Pt100

Pt1000/NTC/PTC

OP4

(note)

DI2

(note)

Ananogue Input

12 Vdc 

(note)

12 Vdc 

(note)

PV

PV

4... 20 A

3 wire transmitter

2 wire 

transmitter

OP1

TERMINALS

Note: 

Terminal 4 can be programmed as:

-  Digital Input

 (DI2) connecting a free of voltage contact between terminals 4 and 11;

-  0... 12 V SSR Drive Output 

(OP4) connecting the load between terminals 4 and 11;

-  12 Vdc transmitter power supply

 connecting the 2 wire transmitter between terminals 4 and 1; 

for 3 wire transmitter connect terminal 4 to transmitter power supply input and terminal 1 and 2 to transmitter signal output.

:  Out4 has a Logic Level 1 of: 12 VDC ±20%, 20 mA max.

mA

L

Pin:

q

2.5 mm (0.1 in.) max.

Stripped wire: L 5.5 mm (0.21 in.)

Neutral Line

Power supply

MOUNTING

DIMENSIONS

Overall dimensions (L x H x D):  78 x  35 x 69.5 mm 

(3.07 x 1.37 x 2.73 in.)

Panel Cut-out (L x H): 

71+0.6 x 29+0.6 mm 
(2.79+0.023 x 1.14+0.023 in.)

 Attention

The controller can be installed using 2 different types of brackets.
Follow the sequence 1, 2a, 3a for the screw bracket (collar 
bracket for IP65), the sequence 1, 2b, 3b for the “butterfly” 
brackets (2 pieces).

2a

2a

3b

3b

1

3a

3a

1

2b

2b

KR1E

KR1E

KR1E

Press for 2 seconds 

the key

PARAMETERS SETTING

CONTROLLER DISPLAY

Increases the displayed value

Confirm value and pass to the next parameter

Decreases the displayed value

Parameter setting

To exit the parameters configuration procedure, press
       for 3 seconds or wait for the end of the delay 
(about 10 seconds)

The 

KR1E-xDRRRDxx

 controller is pre-configured (default 

configuration) for wine applications where there is the 
need to cool or reheat in thermostatic mode (on/off with 
hysteresis) a tank with a PT100 probe in mono relay 
output (Heat and Cool on OP1).

Heat mode

The controller action type can be identified by the color of the upper display (measurement):

Red

Heat mode only

Green

:  Cool mode only

Orange

: The controller responds to temperature changes and selects the appropriate control mode 

by operating the appropriate control output and displaying the setpoint to be reached.

The numbered red LEDs indicate, when lighted, the active (on) state of the corresponding relay output.

Cool mode

Automatic Heat/Cool

selection

2 s

KR1E

KR1E

KR1E

KR1E

Line

KR1E

Power Supply

A

24Vac (-25... +12%) or 24Vdc (-15... +25%)

L

100... 240 Vac (-15... +10%)

H

Input + Ditigal input1 

B

PT100, PT1000, mA + Digital Input 1

D

PTC, NTC, mA + Digital Input 1

P

Output OP1 (control output)

C

Relay (1 SPST NO, 4 A/250 Vac)

R

Output OP2 (control output)

D

Relay SPST NO 2 A/250 Vac (resistive load)

R

Output OP3 (alarm output)

E

None

-

Relay SPST NO 2 A/250 Vac (resistive load) selectable if Output 1 is present

R

Output OP4 (configurable)

F

Digital I/O (see the Electrical Connections paragraph for details)

D

Serial Communications

G

TTL Modbus

-

RS485 Modbus

S

Terminal Type

H

Standard (screw type non removable terminal blocks)

-

With plug-in screw type terminal blocks

E

With plug-in clamp type terminal blocks

M

With plug-in terminal blocks (fixed part only)

N

Model Code example: 

KR1E-LDRRRD-E

KR1E controller for Wine applications

 

-

Power supply: 24Vac/dc,

 

-

Inputs: PT1000 or 4... 20 mA;

 

-

Digital Input 1,

 

-

3 Relay Outputs (OP1: Alarm, OP2: Cold, OP3 Alarm),

 

-

Confiigurable OP4: Digital Input 2 or Transmitter power supply,

 

-

TTL Port,

 

-

Removable screw type terminals.

Parameters List (

PASS

: 30)

Group Param.

Description

Value range or selection list

Default

User 

selection

Note

inp

node

Control mode selection

1  Heat (SP on Out1)

 

or

 Cool (SP2 on Out1),

Heat (SP on Out1) 

or

 Cool (SP2 on Out2),

3  Heat (SP on Out1) 

and

 Cool (SP2 on Out2),

4 Heat

(SP on Out1)

 

or

 Cool(SP2 on Out2)

 

or

  

Heat 

(SP on Out1)

 

and

 Cool (SP2 on Out2),

5 Heat

 (SP on Out1) 

or

 Cool (SP on Out1),

6 Heat

 (SP on Out1)

 

or

 Cool (SP on Out2),

7 Heat 

(SP on Out1)

 

and

 Cool (SP on Out2),

8  Heat (SP on Out1)

 

or

 Cool (SP on Out2)

 

or

  

Heat

 (SP on Out1)

 

and

 Cool (SP on Out2).

1

sEns

Measurement input type

Pt1 

Pt100

Pt10  Pt1000

4.20  4… 20 mA

Pt1

dp

Decimal point position

0... 3

0

diF1

Digital input 1 function

Stby  Mode Standby (transition)

Stb2  Mode Standby (status)

HC.tr  Heat <-> Cool (transition)

HC.St  Heat <-> Cool (status)

nonE

diF2

Digital input 2 function

nonE

di.a

Digital Inputs Action

0... 3

0

See the manual for details

Pan

usrb

Key

 

 function

Stby  Standby Mode

1H2C  Heat <-> Cool toggle

HC.Sb  Heat <-> Cool and 

 

Auto <-> Standby

Auto

If 

HC.Sb

: a 1 s pressure 

toggles between 

 

Heat <-> Cool mode.

A 5 s pressure puts the 

controller in standby

ser

Add

Controller Modbus address

1... 254

1

Modbus RTU slave 

Protocol

bAud

Modbus transmission speed

1200, 2400, 9600 baud,

19.2, 38.4 kbaud

9600

Notes: 1. 

Several successive pressures on the   key allow the various groups of parameters to be scrolled.

 2. 

A long pressure on the    key allows to exit the Configuration mode and return to the operator mode

Parameters List (

PASS

: 20)

Param.

Description

Value range or selection list

Default

User 

selection

Note

OpEr

Operative mode selection

reg 

Auto,

stby  Standby

reg

st.by

: Control action stopped

reg

: Control action running

SP

Set point 1

-1999... +9999 (Engineering Unit) 0

SP2

Set point 2

-1999... +9999 (Engineering Unit) 0

HstH

Heat Hysteresis

0... 9999 (Engineering Unit)

1

HstC

Cool Hysteresis

0... 9999 (Engineering Unit)

1

AL1

Alarm 1 threshold (Low)

AL1L... AL1H

0

AL2

Alarm 2 threshold (High)

AL2L... AL2H

80

dP

Decimal point position

0... 3

0

SPLL

Setpoint Low Limit

From 0 to the SPHL value

0

SPHL

Setpoint High Limit

From the value of SPLL to 1999

90

FiL

Digital filter on the measured value 0 

oFF

0.1... 20.0 s

1.0

HAL1

Alarm 1 Hysteresis

0...9999 (Engineering Unit)

1

HAL2

Alarm 2 Hysteresis

0...9999 (Engineering Unit)

1

Al.o

Adjust Low Offset

-300…+300 (Engineering Unit)

0

Note: 

Several successive pressures on the

 

 key allow to scroll the available Control parameters.

Pressing no keys for 5 s

, the controller automatically exits 

PASS20

 menu and returns to the standard display and the current measurement.

Reviews: