Ascon tecnologic AET1 User Manual Download Page 1

Ascon Tecnologic - AET1 - USER MANUAL - Vr. 1.0 PAG. 1

AET1

TTL To EThErnET TCP/IP 

GaTEway

User Manual

Code: ISTR-MAET1ITAENG01 - Vr. 1.0 (ENG)

ascon Tecnologic S.r.l.

Viale Indipendenza 56, 27029 Vigevano (PV) - ITALY

Tel.:

 +39 0381 69871 - 

FaX:

 +39 0381 698730

site:

 

www.ascontecnologic.com

e-mail:

 

[email protected]

ForEword

D

D

This manual contains the information necessary for 
the installation, use and maintenance of the product, 
we therefore recommend that the utmost attention is 
paid to the following instructions and to save it.

This document is exclusive property of Ascon Tecnologic 
which forbids any reproduction and divulgation, even in part, of 
the document, unless expressly authorized.  Ascon Tecnologic 
reserves the right to make any formal or functional changes 
at any moment and without any notice.
Ascon Tecnologic and its legal representatives do not 
assume any responsibility for any damage to people, things 
or animals deriving from violation, wrong or improper use or 
in any case not in compliance with the instrument features.

D

D

Whenever a failure or a malfunction of the device 
may cause dangerous situations for persons, thing 
or animals, please remember that the plant must be 
equipped with additional electromechanical devices 
which will guarantee safety.

Disposal

The appliance (or the product) must be disposed 

of separately in compliance with the local standards 

in force on waste disposal.

1  oUTLInE dIMEnSIonS (mm)

TTL

PWR

RX

TX

27.80

87.50

95.30

31.18

DIN rail
mounting

78.65

21.55

M4

Screw mounting 
holes

M4

TTL

PWR

RX

TX

A

B

Connectors
detail

1.1  Mounting requirements

This instrument is intended for permanent installation, for 
indoor use only, in an electrical panel which encloses the rear 
housing, exposed terminals and wiring on the back.  Select a 
mounting location having the following characteristics:

1. 

It should be easily accessible;

2. 

There is minimum vibrations and no impact;

3. 

There are no corrosive gases;

4. 

There are no water or other fluids (i.e. condensation);

5. 

The ambient temperature is in accordance with the 
operative temperature (0... 50°C);

6. 

The relative humidity is in accordance with the instrument 
specifications (20... 85%).

2  ConnECTIon dIaGraM

2.1  General notes about wiring

Do not run the communication cables (TTL or Ethernet) 
together with power cables.

2.2  TTL Connection

2.2.1  Cable identification

Cable models: 

CATTL D020;

Identification:

  Both side with a black tube.

P1

1

5

P2

1

5

BLACK

BLACK

2.3  Ethernet Connection

The Ethernet connection is made with a standard Ethernet 
cable with RJ45 connectors.

3  how To ProCEEd

1. 

Connect the CATTL cable to the instrument that must be 
connected to the Ethernet network;

2. 

Power ON the instrument;

3. 

Plug the second side of the CATTL into connector 

B

;

4. 

If the LED 

Pwr

 turns ON, the connection is correct, 

otherwise, disconnect the CATTL cable from 

B

 connector 

and plug it into connector 

a

;

5. 

The LED 

Pwr

 turns ON.