INSTALLATION GUIDE

Corridor Lamp 4

Summary of Contents for NICL4

Page 1: ...INSTALLATION GUIDE Corridor Lamp 4...

Page 2: ...tant Safety Information 4 5 Mounting 5 5 1 Mount the NICL4 base onto a backbox 5 5 2 Mount the Base without a Backbox 6 6 Connections and DIP Switch Settings 8 7 Setting the Corridor Lamp ID 10 8 Term...

Page 3: ...rmation Caution Use extreme caution and follow instructions carefully Caution Bright LEDs behind translucent dome cover High brightness light is produced by the LED boards that are placed onto the NIC...

Page 4: ...corridor lamp supports up to 4 LED boards NILD2 NILD4 RGB behind a translucent dome cover The NICL4 is connected to the room bus with an RJ45 cable using the Ethernet standard T 568B color coding The...

Page 5: ...to be installed must be clean dry and weatherproof The walls on which devices are to be installed should be finished painted wall papered etc before the devices are installed It is important to have t...

Page 6: ...ons for use during installa tion and maintenance of the NICL4 To ensure a safe working environment during the installation and operation of the NICL4 the following safety symbols appear throughout thi...

Page 7: ...her particles when applying maintenance to an NICL4 that is mounted inside a clinical area 5 1 Mount the NICL4 base onto a backbox 1 Place the base over the backbox with the spring type holding clip p...

Page 8: ...cables are located If the connecting cables are run inside the wall locate the base of the NICL4 over the hole where the cables exit from the wall If the connecting cables are run in a channel outsid...

Page 9: ...t See Figure 1 NICL4 Base Orientation and Cutouts page 6 items 3 3 Using the base as a template mark four holes for the screws using the slotted fitting holes located in the base 4 Remove the base spa...

Page 10: ...efore attaching the PCB to its base make all wire connections and DIP switch settings Be sure that required cables are properly connected The following figures show the locations for each cable Figure...

Page 11: ...P Switch Settings Figure 3 NICL4 Circuit Board Back Legend 1 DIP switches for Corridor Lamp ID selection 2 Buzzer 3 RJ45 room bus connectors for connection to NIRC4 room controller and NU series PDs v...

Page 12: ...ates the DIP switch found on the back of a NICL4 circuit board Figure 4 Corridor Lamp ID Selection DIP Switch The following table shows the DIP switch settings for all IDs DIP switch settings for corr...

Page 13: ...rs that allow feeding excess wire length through the connector When crimping the excess wire length will be cut automatically Easy RJ45 connectors are not included and must be ordered separately Easy...

Page 14: ...Terminating and Mounting the Room Bus RJ45 Connectors INSTALLATION GUIDE Corridor Lamp 4 Figure 5 Room Bus Connections 12 TD 93352EN 25 January 2021 Ver A...

Page 15: ...board are not in the centre of the board therefore it is important to make sure that the LED lamp board lines up with the guide marks on the corridor lamp PCB when the pins are inserted The LED lamp c...

Page 16: ...Ascom Sweden AB Grimbodalen 2 SE 417 49 G teborg Sweden Phone 46 31 55 93 00 www ascom com TD 93352EN 25 January 2021 Ver A last page...