background image

TD 92232GB

2005-06-15 / Ver.G

Installation Guide

ELISE2

Summary of Contents for ELISE2

Page 1: ...TD 92232GB 2005 06 15 Ver G Installation Guide ELISE2...

Page 2: ...Units 13 4 7 System 900 Addressing 14 4 8 Connection of System Bus 14 4 9 Connection of Supply Voltage 16 4 10 Additional Connections 17 4 11 Activation of Battery 19 4 12 Setup of Network Parameters...

Page 3: ...nt and therefore described in the application documentation The parameter setup of ELISE2 is done with a web browser Figure 1 The ELISE2 module Supply voltage 12 24 V DC 10 Current consumption max 0 4...

Page 4: ...ard Description Figure 2 The ELISE2 circuit board 002 J2 IC2 J10 J16 J15 J4 J13 J12 J11 J8 J7 J24 J14 J6 J5 J20 S3 LED6 RS232 3 ETH 900 900 RS232 2 RS232 1 LED7 S4 S5 S1 S2 IC24 J22 J9 IC1 CPU BAT1 SW...

Page 5: ...e is not used J1 Jumper that activates the backup battery Jumper pin 2 3 to activate J4 For grounding and production test J15 Jumper that determines if the Error relay output should be active when the...

Page 6: ...ISE2 restarts wait until the Function Indicator is not indicating starting up flashing orange before pressing SW4 again Restart There are two ways to restart an ELISE2 following the instruction above...

Page 7: ...ence How the mode functions is application dependent For more exact information about the functionality during unlicensed mode see the application documentation In unlicensed mode it is possible to en...

Page 8: ...Set all sections on SW3 to OFF 2 Open the page System Setup General on the administration web page and check that the correct licence is entered 3 Press Reboot 3 5 Function Indicator Figure 4 Status...

Page 9: ...ation and Authentication Administration on ELISE2 is done from a web browser In order to access the administration pages a user name and password have to be given IMPORTANT The default passwords have...

Page 10: ...alled ftpuser and the default password is changemetoo The user is available in products with a FTP area The user can change its own password on the following page http xxx xxx xxx xxx admin public ftp...

Page 11: ...ructions in 4 7 System 900 Addressing on page 14 6 Connect the system bus follow instructions in 4 8 Connection of System Bus on page 14 and 4 9 Connection of Supply Voltage on page 16 7 Optionally co...

Page 12: ...itable section 2 Run the wiring out through the partition Wiring can be run three ways from the ELISE2 module Remove the rectangular covers and run the cabling out through the side 1 Break off section...

Page 13: ...to communicate with for example an Alarm Module or Output Module The same information that can be received when the ELISE2 is connected to an A bus with Central Unit can also be received when it is co...

Page 14: ...Distribution on page 24 and documentation for the System 900 Required Hardware Modifications When ELISE2 shall control the communication on the A B bus jumper points S4 and S5 has to be soldered see...

Page 15: ...ree space of about 150 mm above and 50 mm below the unit 4 6 Mounting Together with Other Units 1 Remove the rectangular 1 and circular 2 covers 2 The rectangular covers are used to fasten units to ea...

Page 16: ...e same as any other System 900 unit address see document System Installation On site Paging System TD 90227GB for more information Figure 8 The ELISE2 module addressing switch 4 8 Connection of System...

Page 17: ...other unit Note Make sure connectors are correctly inserted Bus Connection to Screw Terminals If system bus cable is not used connections are made with twisted pairs to screw connector J24 Figure 9 Co...

Page 18: ...stallation On site Paging System TD 90227GB under Power Supply Figure 10 Connection of supply voltage Figure 11 Ferrite bead attached and wired in the module 1 To be able to fit the ferrite bead break...

Page 19: ...ring is set to 1 2 the circuit is open and the error relay output is inactive At power up or restart of the ELISE2 the relay is released until the applications are working properly If the relay is rel...

Page 20: ...uts are software dependent Two digital inputs and two digital outputs can be connected via J16 The outputs are of open collector type and the output signals are dimensioned for 100 mA at max 12 V A pu...

Page 21: ...battery by closing jumper J1 on the circuit board Jumper pin 2 3 to activate Figure 17 Battery placement The backup battery is a 3V lithium battery At any interruption in the ordinary power supply the...

Page 22: ...e network setup IP address 192 5 36 229 If the function indicator is red check that supply voltage is 12 5 Vdc 10 4 To be able to access ELISE2 from a PC the PC has to belong to the same network as EL...

Page 23: ...OFF Reboot ELISE2 by navigating to Reboot 10 Return to the program Route to ELISE and press Detach to remove the ELISE2 network setup IP address from the route table Close the program 11 When ELISE2...

Page 24: ...s If the indicator continues to flash orange check Connections on ELISE2 ELISE2 has a correct System 900 address Note Check also the application documentation for trouble shooting information If the i...

Page 25: ...tion specific pages The administration pages that are common to all ELISE2 will display date and time in the following format YYYY MM DD HH MM SS for example 2000 01 31 13 30 00 This format for date a...

Page 26: ...onfigured to distribute the data to a module It is also possible to address the System 900 interface on another module by entering its IP address instead of 127 0 0 1 localhost Module addressing 127 0...

Page 27: ...into the cabinet 6 If the Compact Flash is not preprogrammed with a valid IP address follow the instructions in 4 12 Setup of Network Parameters on page 20 else connect the power cable 7 Replace the c...

Page 28: ...hat handles the remote connection 5 4 Installing an Image on an empty Compact Flash An image can also be installed on an empty Compact Flash 1 Set section one and four in SW3 to ON to set the ELISE2 i...

Page 29: ...the screw connectors from the circuit board 1 4 Press the four holding clips to release the circuit board 2 5 Remove the circuit board 3 6 Install the new circuit board in the case and make sure the c...

Page 30: ...flash micro controller J3 Male connector to be put on J9 on ELISE2 circuit board Pin 12 cut off J4 Male connector to be put on J10 on ELISE2 circuit board SW1 For service IC1 Flash memory IC3 Neuron...

Page 31: ...pins of the LPB with the female connector of the ELISE2 then press the LPB down firmly To avoid misalignment the pin 12 on the J3 connector of the LPB is cut off and the corresponding hole on the J9...

Page 32: ...cm Only use pins 1 and 2 for connection of the LON bus in out Pins 3 and 4 can be used for connection of other LON devices for example SLA See figure 22 below Figure 22 Cabling of screw connector J1 6...