3.3  Instructions for transport

 

Transport the Electric Range only in the Original Packing. Do not raise or move the appliance using the 
top plate, the lower edges on the side or the door handle. Use the lower edge at the front or at the back 
instead. 

3.4  Installation instructions 

The  equipment  is  wired-up  internally  in  the  works  as  far  as  the  power  supply  connector.  All  external 
connection  work  must  be  carried  out  by  an  authorised  specialist  company.  Let  the  specialists  look  at 
these documents. The legally recognised regulations (Germany VDE, Austria ÖVE, Switzerland SEV etc.) 
and the connection conditions of the local electricity utility are to be observed.  

Before beginning the installation work, it should be checked that the mains voltage, mains type and the 
current rating of the fuse match the values given on the type plates. An isolating device in the customer's 
scope  of  supply  that  is  effective  on  all  poles  must  be  provided,  e.g.  contactor  fuses  with  at  least  3  mm 
contact gaps, so that the equipment is disconnected from the power supply during repair and installation 
work. Connection to an equipotential bonding system is available (check effectiveness).  

Do not sharply bend or pinch power supply cables or damage them on sharp edges and route them so 
that  they  do  not  come  in  contact  with  hot  parts.  The  power  supply  cable  must  be  led  through  the 
equipment, fully sheathed, from the screwed connection to the entry of the terminal box. The equipment 
is intended for a permanent connection; connection via plug and socket is not permitted 

4  Installation 

4.1  Setting up 

Do  not  set  up  the  equipment  next  to  walls,  kitchen  furniture,  decorations  or  similar  which  are  made  of 
flammable  materials.  Otherwise  there  is  danger  of  fire.  See  connection  diagram  with  equipment 
description for minimum distance. Local fire protection regulations must be kept to absolutely! 

It is absolutely necessary that the equipment be set up horizontally (use spirit level for alignment) so that 
the  doors  can  be  opened  and  closed  without  any  problem  and  that  they  seal  tightly  when  closed. 
Equipment  with  adjustable  feet  can  easily  compensate  for  unevenness  in  the  floor  (+/-  20  mm)  by  the 
turning  of  the  bottom  end  of  the  stainless  steel  feet.  If  set  up  on  a  plinth,  this  is  to  have  an  underlay  if 
needed. 

4.1.1  Free-standing set-up 

If the equipment is to be set up on its own, suitable means are to be used to protect it against tilting and 
shifting. 

4.1.2  Setting up in groups or blocks 

When  setting  them  up  in  groups  or  blocks,  the  equipment  must  be  joined  together  by  connecting 
elements provided for this purpose. This is for the sake of hygiene. Observe equipment setting up sheets 
or assembly diagram (data sheet in annex) 

4.2  Connections 

Details  of  connections  for  the  media  can  be  taken  from  the  accompanying  connection  diagram  and 
equipment description. Check whether the size and position of the electrical connections of the customer 
side correspond to the information in the connection plan, equipment description or installation plan. 

The  terminal  box  for  the  connections  is  located  behind  the  front  panel  A  (see  data  sheet).  Make  the 
connections  as shown  in  the annex  or  or  in  the connection  diagram  accompanying  the  equipment.  The 
number of the connection diagram is to be found on the type plate. Once the electrical connections have 
been made, close the cover of the terminal box and screw the front panel in place again. 

4.2.1  Floor-standing appliances 

The  connections  can  be  made  from  below  or  from  the  rear  from  a  closed  installation  space.  With  the 
connection from below, the pipe length must be 50 mm above the floor surface. 

4.2.2  Connection from the rear when equipment on a plinth 

The penetrations are to be made according to the known DIN and VDE regulations. The connections can 
be through the rear wall (see illustration for dimensions). 

Summary of Contents for 6700.400

Page 1: ...Operating Instruction ASCOLINE 850 MEH 2xx 4xx 6xx Electric Range With steel hot plate Quality and Expertise in Stainless Steel ...

Page 2: ...lts and their Rectification 7 7 1 Disconnect the appliance from power supply before starting any maintenance 7 8 Spare Parts 8 8 1 Liste 8 8 2 Illustrations 9 9 Declaration of Conformity 12 Annexes Technical Data Sheet Connection Diagram Cleaning and Care Instructions Dear customer Read carefully through these operating instructions before putting the equipment into operation for the first time It...

Page 3: ...e announced to the employees concerned when they are trained in how to use the appliance The appliance must not be left unattended when in operation You should only operate it in a sufficient ventilated room Do not install the appliance next to walls kitchen furniture decorations or other inflammable materials Otherwise fire hazard See minimum distance in the wiring diagram with description Pay at...

Page 4: ...materials Otherwise there is danger of fire See connection diagram with equipment description for minimum distance Local fire protection regulations must be kept to absolutely It is absolutely necessary that the equipment be set up horizontally use spirit level for alignment so that the doors can be opened and closed without any problem and that they seal tightly when closed Equipment with adjusta...

Page 5: ...h smooth bottom Rough bottoms scratch the surface when moving otherwise the temperature transfer with smooth and flat bottom is more effective Turn the knob for thermostat to the right The cooking zone heats up and the green pilot lamp lights up After some minutes in open circuit the heating of the cooking zone is lowered Initial cooking at high output settings continuous cooking at lower setting ...

Page 6: ...jet or high pressure cleaners When cleaning the surrounding of the appliance with water steam jet or high pressure cleaner turn the appliance of Before the appliance is cleaned it must be switched off and allowed to sufficiently cool down Parts of the appliance or accessories that come in contact with food must be thoroughly rinsed with drinking water after being cleaned with cleansing agent Do no...

Page 7: ...resden Grüner Weg 29 Deutschland Tel 0351 4533 0 Fax 0351 4537 339 E Mail service ascobloc de MEH2xxff_e doc Stand 18 1 2012 Subject to change without notice 6 6 2 Measures when not in operation for a longer period Clean the equipment thoroughly Isolate the equipment from the power supply ...

Page 8: ...place heating element Fuse switch off again and again Wrong fuse protection or short circuit Check Replace or repair Steel plate and control panel will be very hot Cross flow radiator out of order do not continue use of range replace cross flow radiator Baking oven door do not close properly Spring power not enough Set the spring stronger Baking oven leakable Gasket worn out Replace gasket Green s...

Page 9: ...r 5 phase switch 08 2947 9 Graduated collar Upper lower heat convection MEH414 416 443 445 614 616 08 2909 10 Graduated collar for change over switch MEH416 445 616 08 2916 11 Wing hinger A MEH 614 616 04 5252 12 Wing hinge B MEH 614 616 04 5253 13 Control knob 09 2662 14 Change over switch MEH416 445 616 09 2197 X 15 Steel plate MEH 211 411 414 416 610 MEH 614 616 06 22104 X 16 Solid steel plate ...

Page 10: ...xxff_e doc Stand 18 1 2012 Subject to change without notice 9 convection temperature begrenzer 27 Signal lamp green 09 2092 X 28 Signal lamp yellow 09 2093 X 29 Switch steel cooking zone 09 1323 X 30 Foot of appliance 08 6232 31 Flat spring for con trol knob 12 3657 X change or repair only by authorized personal 8 2 Illustrations Illustration 1 Control panel for instance MEH 416 MEH445 ...

Page 11: ...ner Weg 29 Deutschland Tel 0351 4533 0 Fax 0351 4537 339 E Mail service ascobloc de MEH2xxff_e doc Stand 18 1 2012 Subject to change without notice 10 Illustration 2 Installation hole behind control panel witout ventilation guide sheet Illustration 3 steel cokking zone from down not MEH 440 443 445 ...

Page 12: ...ätebau GmbH 01156 Dresden Grüner Weg 29 Deutschland Tel 0351 4533 0 Fax 0351 4537 339 E Mail service ascobloc de MEH2xxff_e doc Stand 18 1 2012 Subject to change without notice 11 Illustration 4 Baking oven without baking oven bottom without rack for baking sheets grids ...

Page 13: ...6 Electric range 3 steel cooking zone baking oven with convection 6708 400 satisfy the provisions of the EMC Directive 2004 108 EC of the Low Voltage Directive 2006 95 EC including modifications valid at the time of the declaration The following harmonised standards were applied DIN EN 55014 1 2010 02 Electromagnetic compatibility Requirements for household appliances electric tools and similar ap...

Reviews: