2.5
Installation and assembly
Units represented in this manual are intended for indoor use only. Be sure the location chosen has a
floor strong enough to support the total weight of the unit and contents. For the most efficient operation,
be sure to provide good air circulation inside and outside of the unit.
INSIDE CABINET
The first cleaning must be made when you unpack the unit and before switching it on. Clean it
with water and a mild detergent. When it is clean and dry, insert the accessories in the
appropriate places, for the best use of the user.
OUTSIDE CABINET
Be sure the unit has good air circulation around it. Avoid hot corners and locations near stoves
and ovens. It is recommended the unit be installed no closer than 2” from any wall. The place
where the refrigerator is placed must be open and clean, avoiding that de fan of the condensing
unit absorbs materials which are deposited then into the condenser blades and coil, which can
produce failures.
The unit should not be installed under ambient temperatures higher than 100 °F.
If the relative humidity is higher than 60 %, the door frames may sweat water. This is not a
malfunctioning of the unit.
2.6
Connections
Refer to the amperage data in this manual or on data plate and your local code or the National Electrical
Code to be sure unit is connected to the proper power source. Verify correct incoming voltage according
to the Data Plate information.The data plate in located inside the unit, near the top front left corner.
Under any circumstances should the data plate be removed from the unit. The data plate is essential to
identify the particular features of your unit and is of great benefit to installers, operators and
maintenance personnel. It is recommended that, in the event the data plate is removed, you copy down
the essential information in this manual for reference before installation.
OPERATION
3.1 General information.
3.2 Control panel description.
3.3 Machine settings and programs.
3.1
General information
Good air flow inside the cabinet is critical. Do not block air flow to the fans. Allow three inches of space
along the front, back, and sides.
3.2
Control panel description
3.2.1
Electronic Control
After connecting your unit, turn ON rocker switch located next to the controller. The display will
light up showing the temperature inside the unit. Also, the compressor and fan icons will flash
for a period of three minutes. After this delay the unit will start cooling.
Verify you don't have any alarms on the temperature controller. If after you turn ON the
equipment the controller shows the alarm icon or an error code, call for technical service. They
will help you fix the problem.