background image

 

 

10

asberprofessional.com

 

 

 

 

 

 

 

 

 

 

 

 

 

asberprofessional.com

 

 

TROUBLE SHOOTING 

PROBLEM 

PROBABLE CAUSE 

REMEDY 

Pilot  will  not 
light  

a.

 

No gas  

b.

 

Gas  tap  dial  not  set  at  “Pilot” 
position and depressed. 
 

a.

 

Turn main gas valve “ON” 

b.

 

Set  gas  tap  dial  on 
combination  gas  valve  to 
“Pilot”.  Depress  and  hold 
while lighting. 

Pilot  will  not 
stay lit  

a.

 

Gas  tap  dial  not  depressed 
and held long enough 

b.

 

Defective thermopile  

c.

 

Pilot  flame  not  properly 
adjusted   

a.

 

Depress  and  hold  for  at 
least 30 sec. 

b.

 

Replace  

c.

 

Adjust  pilot  flame  whit 
pilot  adjustment  screw  on 
the combination valve.   

Main  burners 
will not ignite  

a.

 

Pilot not lit  

b.

 

Thermopile 

not 

properly 

installed in the pilot. 

c.

 

Gas  tap  dial  not  set  at  “ON” 
position. 

d.

 

Thermostat  not  set  at  any 
temperature. 

e.

 

Defective gas valve. 

f.

 

Defective hi-limit switch. 

a.

 

Light the pilot  

b.

 

Push  in  ad  tightens.  Pilot 
flame  should  engulf  the 
thermopile. 

c.

 

Turn and set gas tap dial to 
“ON” position.  

d.

 

Set  thermostat  to  desired 
temperature.  

e.

 

Replace 

f.

 

Replace. 

Fryer  does  not 
heat up fast  

a.

 

Insufficient gas. 

b.

 

Line clogged 

c.

 

Overloading the fryer. 

a.

 

Check gas pressure. 

b.

 

Remove and clean gas line  

c.

 

Cook  smaller  loads.  Need 
larger fryer! 

Oil/shortening 
scorches 

and 

breaks down. 

a.

 

Operating  temperature  too 
high. 

b.

 

Thermostat out of calibration  

c.

 

Oil/shortening overused. 

d.

 

Oil/shortening  not  filtered 
frequently. 

a.

 

Set at proper temperature. 

b.

 

Re-calibrate 

c.

 

Replace  

d.

 

Replace 

 

Temperature 
cannot 

be 

controlled  

a.

 

Thermostat bulb out of proper 
position. 

b.

 

Thermostat out of calibration. 

c.

 

Defective thermostat. 

d.

 

Defective gas valve. 

a.

 

Relocate and secure at the 
proper position. 

b.

 

Re-calibrate. 

c.

 

Replace. 

d.

 

Replace. 

Fryer  shut-off, 
cannot  re-light 
pilot  

a.

 

Hi-limit cut off. 

b.

 

Defective thermostat.  

c.

 

Thermostat out of calibration. 

d.

 

Hi-limit switch defective. 

a.

 

Note:  cannot  re-light  the 
pilot  until  temperature  of 
oil  drops  to  about  325°F. 
call service, if uncertain.  

b.

 

Replace. 

c.

 

Re-calibrate 

d.

 

Replace.  

 

 

Summary of Contents for AECM-24

Page 1: ...s Installation and Operation Manueltalimatlar Kurulum ve al t rma Manual de instrucciones Uso y mantenimiento Manuel d instructions Installation et fonctionnement Bedienungshinweise Installation und B...

Page 2: ...n and assembly 3 2 3 1 UNCRATING 3 2 3 2 INSTALLATION 3 2 4 Gas Connections 4 2 4 1 MANUAL SHUT OFF VALVE 5 2 4 2 PRESSURE REGULATOR 5 2 4 3 THIS APPLIANCE IS EQUIPPED FOR NATURAL GAS 5 2 4 4 PRESSURE...

Page 3: ...design engineered for commercial use only 1 2 IMPORTANT SAFETY INFORMATION WARNING Improper installation adjustment alteration service or maintenance can cause property damage injury or death Read the...

Page 4: ...damage to the equipment notify the carrier immediately Notification should be made verbally as well as in written form Request an inspection by the shipping company of the damaged equipment Retain al...

Page 5: ...te on freight bill or express delivery and signed by person making delivery File claim for damages immediately Regardless of extent of damages Concealed loss or damage If damage is noticed after unpac...

Page 6: ...4asberprofessional com asberprofessional com 1 Place the support to the wall 2 Put the equipment and use the screw to fasten the equipment to the support 2 4 G a s C o n n e c t i o...

Page 7: ...must be installed at the gas inlet of each piece of equipment The regulators supplied along with ASBER appliances will have 3 4 inlet outlet openings and are adjusted at the factory for 5 WC natural g...

Page 8: ...el who are familiar and experienced with local installation codes Before Installation please read instructions completely and carefully Do not remove permanently affixed labels warnings or plates from...

Page 9: ...e appliance for easy servicing Provision should be made for any commercial heavy duty cooking appliance exhaust combustion waste products to the outside of the building Usual practice is to place the...

Page 10: ...tdown shut OFF gas valve s and turn pilot valve s adjusting screw clockwise to shut off gas to the pilot s 3 3 DAILY SHUT DOWN At the end of the day turn the gas tap dial on the combination gas valve...

Page 11: ...efully scrape spillovers from the drip tray below the cooking surface 2 Wash all exterior and interior surfaces with hot soapy water solution Do not use any abrasives on any portion of the stainless o...

Page 12: ...e thermopile c Turn and set gas tap dial to ON position d Set thermostat to desired temperature e Replace f Replace Fryer does not heat up fast a Insufficient gas b Line clogged c Overloading the frye...

Page 13: ...sberprofessional com ASBER Circuito Exportaci n N 201 Parque Industrial Tres Naciones San Lu s Potos S L P M xico 13105 NW 47th Ave Miami Fl 33054 www asberprofessional com MULTI SOLUTION MANUFACTURER...

Reviews: