Asami AMV5-22SLD Owner'S Manual Download Page 24

Multi Variable Air Conditioners Floor and Ceiling Type Indoor Unit 

 

20 

6 General Maintenance 

 

Warning!

 

Before the cleaning, turn unit off and disconnect power supply. Otherwise, it may result in electric shock 

or personal injury. 

When cleaning the air conditioner, please use stable standing platform. 

Do not clean the unit using hot water of over 45 to prevent the unit from losing color or deforming. 

Do not dry the unit on fire resources, otherwise the filter may get on fire or unshaped. 

Volatile liquid like thinner or gasoline will damage the air conditioner. (Use soft dry cloth and wet cloth 

dipped with mild detergent to clean the filter of air conditioner.) 

If any problem, please contact after-sales service agent for assistance. 

6.1 Cleaning of Air Filter 

1

 

Remove the air filter on the air inlet for cleaning. Use a dust catcher or water to clean it. If the filter is 
very  dirty(e.g.  greasy),  you  can  clean  it  using  warm  water(below  45

)  that  is  mixed  with  mild 

detergent. Then let it dry naturally under cool places. 

2

 

If the air conditioner is used in dusty place, clean the air filter often(generally once every 2 weeks). 

6.2 Maintenance Before Use-season 

1

 

Check whether air inlets and air outlets of indoor units and outdoor units are blocked. 

2

 

Check whether grounding wire is in good condition. 

3

 

Check whether wire connection is correct. 

4

 

Connect the power and check whether the display screen of wired controller shows any characters. 

6.3 Maintenance After Use-season 

1

 

When the weather is sunny, operate the air conditioner for half a day to let its inner part dry. 

2

 

If  you  won’t  use  the  air  conditioner  for  a  long  time,  disco

nnect  power  please.  When  power  is 

disconnected, characters on the display screen will disappear. 

7 Malfunction Codes of IDU 

Error 

Code 

Content 

Error 

Code 

Content 

Error 

Code 

Content 

L0 

Indoor Unit Error 

LA 

Indoor Units Incompatibility 

Error 

d8 

Water Temperature Sensor Error 

L1 

Indoor Fan Protection 

LH 

Low Air Quality Warning 

d9 

Jumper Cap Error 

L2 

E-heater Protection 

LC 

Outdoor-Indoor Incompatibility 

Error 

dA 

Indoor Unit 

Hardware Address Error 

L3 

Water Full Protection 

d1 

Indoor Unit Circuit Board Error 

dH 

Wired Controller Circuit Board 

Error 

L4 

Wired Controller Power Supply 

Error 

d3 

Ambient Temperature Sensor 

Error 

dC 

Capacity DIP Switch Setting 

Error 

L5 

Anti-freezing Protection 

d4 

Inlet Pipe Temperature Sensor 

Error 

dL 

Outlet Air Temperature 

Sensor Error 

L7 

No Master Indoor Unit Error 

d6 

Outlet Pipe Temperature 

Sensor Error 

dE 

Indoor Unit CO

2

 Sensor 

Error 

L8 

Power Insufficiency 

Protection 

d7 

Humidity Sensor Error 

db 

Special Code:   

Field Debugging Code 

L9 

Quantity Of Group Control Indoor Units Setting Error 

Summary of Contents for AMV5-22SLD

Page 1: ...onditioners Models AMV5 22SLD AMV5 25SLD AMV5 28SLD AMV5 32SLD AMV5 36SLD AMV5 40SLD AMV5 45SLD AMV5 50SLD AMV5 56SLD AMV5 63SLD AMV5 72SLD Thank you for choosing Air Conditioners please read this own...

Page 2: ......

Page 3: ...re only for your reference For sales or production reasons these graphics are subject to change by manufacturer without prior notice 8 Under the standby status the unit will consume a little power for...

Page 4: ...9 4 3 Installation and Test of Drain Pipe 9 4 4 Installation of Air Duct 12 4 5 Installation of Wired Controller 15 5 Wire Connection 15 5 1 Connection of Wire and Wiring Board Terminal 15 5 2 Power...

Page 5: ...ng into the socket so as to avoid electric shock Please do not connect the ground wire to gas pipe water pipe lightning rod or telephone line Be sure to use the exclusive accessory and part to prevent...

Page 6: ...ay happen Do not expose the unit to the moist or corrosive circumstances Electrify the unit 8 hours before operation Please switch on for 8 hours before operation Do not cut off the power when 24 hour...

Page 7: ...Cooling Heating Fan Dehumidifying Fan Speed Adjustment Temperature Adjustment X fan Function Quiet Function Sleep Function Save Function E heater Function Memory Function Absence Function Timer Functi...

Page 8: ...position 9 others User Manual 1 copy Loosen leaf of Instruction Manual 1 copy harmful substance content table Qualified Certificate 1 copy Bar Code 1 copy 3 2 Location for Installation 1 The top hold...

Page 9: ...ntroller L m feet Wire size mm 2 AWG Material Standard Remarks Light Ordinary polyvinyl chloride sheathed cord 60227 IEC 52 60227 IEC 53 L 250m L 820 1 5feet 2 0 75 2 1 25 2 AWG18 2 AWG16 IEC 60227 5...

Page 10: ...4pc at 40 C ambient temperature when laying across plastic pipe Air switch is D type and used at 40 C If actual installation condition varies please lower the capacity appropriately according to the...

Page 11: ...1000 200 450 474 AMV5 72SLD 1360 415 1300 200 450 474 4 1 2 Punching of Bolt Spots and Bolt Installation Punch holes on the installation area according to the 4 spots on the paper pattern The punching...

Page 12: ...re connection wire of IDU and ODU that need to be connected with the indoor unit Punch holes on the ceiling air return opening or air inlet Ceiling may have to be strengthened to make it level and to...

Page 13: ...be as short as possible and slope downward for at least 1 2 so that condensate can drain out easily 2 Size of the drainage hose must not be smaller than that of the drain pipe 3 Install the drain pip...

Page 14: ...4 3 2 Fig 4 3 3 4 When connecting several drain pipes follow the instruction as indicated in Fig 4 3 4 Choose the drain collecting pipe that matches with unit capacity Fig 4 3 4 5 5 For indoor units t...

Page 15: ...0mm Fig 4 3 9 11 Drain pipes should have a downward slope of at least 1 2 in order to prevent pipes from sagging install hanger bracket at intervals of 1000 1500mm Fig 4 3 10 4 3 3 Test of Drainage Sy...

Page 16: ...off power supply disconnect power cord and then put on the electric box cover 2 Check if the water drains smoothly from the drain pipe and check if there is water leakage on the connection pipe 3 Arr...

Page 17: ...1 Return Air Duct 6 Transition Pipe 2 Canvas Duct 7 Supply Air Duct 3 Return Air Blinds 8 Diffuser 4 Hanger Rod 9 Diffuser Connector 5 Supply Air Outlet 4 4 2 Shape and Size of Air Outlet and Air retu...

Page 18: ...wire 4 Air return from the bottom will produce more noise than air return from the back So we suggest you to add a noise damper and static pressure case to lower noise if you choose air return from t...

Page 19: ...d correct operation 6 Install specialized branch circuit breaker according to related laws and regulations and electrical standards 7 All wiring must use pressure terminal or single wire Multi twisted...

Page 20: ...Use a screwdriver to remove screw on the wiring board of air conditioner 3 Use a round terminal fastener or a plier to securely fasten the round terminal with each core wire of the multi core wire 4 C...

Page 21: ...munication line with the wire clamp on the electric box 5 In order to ensure the reliability of communication between IDU and ODU and the communication among each IDU add a matched resistance supplied...

Page 22: ...Communication between IDU and wired controller is H1 H2 3 One indoor unit can connect two wired controllers master wired controller and sub master wired controller 4 One wired controller is able to co...

Page 23: ...Multi Variable Air Conditioners Floor and Ceiling Type Indoor Unit 19 Fig 5 5...

Page 24: ...its are blocked 2 Check whether grounding wire is in good condition 3 Check whether wire connection is correct 4 Connect the power and check whether the display screen of wired controller shows any ch...

Page 25: ...or windows is open Inlet and outlet of IDU are blocked Setting temperature is too high Refrigerant is insufficient e g refrigerant leakage Poor heating effect The filter is dirty Door or window is op...

Page 26: ......

Page 27: ......

Page 28: ......