Asami AMV-R22G/NaG-D Installation And Operation Manual Download Page 1

                                   

                         

Installation and Operation Manual

Multi Variable Air Conditioners

Wall Mounted Type Indoor Unit

Please read this manual carefully before using this product and keep it properly for future reference.

Models:

A

MV-R22G/NaG-K       

A

MVL-R22G/NaG-K

A

MV-R28G/NaG-K       

A

MVL-R28G/NaG-K

A

MV-R36G/NaG-K       

A

MVL-R36G/NaG-K

A

MV-R45G/NaG-K       

A

MVL-R45G/NaG-K

A

MV-R50G/NaG-K       

A

MVL-R50G/NaG-K

A

MV-R56G/NaG-K       

A

MVL-R56G/NaG-K

A

MV-R63G/NaG-K       

A

MVL-R63G/NaG-K

A

MV-R71G/NaG-K       

A

MVL-R71G/NaG-K

A

MV-R22G/NaG-D       

A

MVL-R22G/NaG-D

A

MV-R28G/NaG-D       

A

MVL-R28G/NaG-D

A

MV-R36G/NaG-D       

A

MVL-R36G/NaG-D

A

MV-R45G/NaG-D       

A

MVL-R45G/NaG-D

A

MV-R50G/NaG-D       

A

MVL-R50G/NaG-D

A

MV-R56G/NaG-D       

A

MVL-R56G/NaG-

D

A

MV-R63G/NaG-D       

A

MVL-R63G/NaG-D

A

MV-R71G/NaG-D       

A

MVL-R71G/NaG-D

Summary of Contents for AMV-R22G/NaG-D

Page 1: ...AMVL R28G NaG K AMV R36G NaG K AMVL R36G NaG K AMV R45G NaG K AMVL R45G NaG K AMV R50G NaG K AMVL R50G NaG K AMV R56G NaG K AMVL R56G NaG K AMV R63G NaG K AMVL R63G NaG K AMV R71G NaG K AMVL R71G NaG...

Page 2: ...use of the rest cool air or the rest heat air in the heat exchanger for preparing for the next operation which is certainly normal When the selected operating mode of the indoor unit conflicts with th...

Page 3: ...UCTURES AND NAMES OF EVERY PART OF THE WALL MOUNTED 5 INDOOR UNIT 5 4 WORKING TEMPERATURE RANGE 6 5 THE BEST USAGE METHOD 6 6 MAINTENANCE METHOD 6 6 1 Cleaning panel 7 6 2 Cleaning the air filters 7 6...

Page 4: ...nds or electric shock may happen Don t insert fingers or sticks or other similar things into the outlet vent otherwise damage may be incurred Cut down the main power switch immediately if a malfunctio...

Page 5: ...l when the air conditioner unit is moved to other place 2 2 The installation of the rear panel Fig 1 A Find the horizontal position by the seton method since the drainage pipe is on the left side it i...

Page 6: ...een inserted on the mainboard through the piping hole of the chassis and the bottom of the appliance upward Please connect the power connection cord with the breaker If the power cord is not long enou...

Page 7: ...e connection cord and wire are led The piping types are recommended B Let the tubing and cord pass though the piping hole after tied up refer to Fig 5 d C Hang the claw behind the indoor unit on the p...

Page 8: ...MV L R36G NaG K AMV L R45G NaG K AMV L R50G NaG K AMV L R56G NaG K AMV L R63G NaG K AMV L R71G NaG K AMV L R22G NaG D AMV L R28G NaG D AMV L R36G NaG D AMV L R45G NaG D AMV L R50G NaG D AMV L R56G NaG...

Page 9: ...y directly for long time and making indoor temperature too low for it is bad for health E Do not pour water to unit or clean it by water otherwise a malfunction or electric shock may happen F Do not m...

Page 10: ...long the arrow direction Fig I Fig II 6 2 Cleaning the air filters Clean it once every 3 months When the usage environment has lots of dust it should be cleaned more frequently A Take down the air fil...

Page 11: ...eliably C Check if the batteries in the wireless remote controller have been replaced D Check if the air filter has been installed properly In order to start up the air conditioner smoothly after it h...

Page 12: ...ecause of the temperature change The air conditioner failed to run Is the power supply cut off Is the power supply connected Is the circuit protector started aside Is the voltage too high or too low I...

Page 13: ...gain to stop the operation 8 2 Adjusting air direction left and right Moving the vertical louver left and right can adjust the left and right direction of air outlet or adjust the air outlet to reach...

Page 14: ......

Page 15: ......

Page 16: ...66129911521...

Reviews: