12.9.5. Misc: Ctrl calibration
Use [Assign 1-3] to enter the desired menu. Use [Assign 4] to cancel the current calibration
routine, and use [Assign 5] to save the current controller calibrations. Use [Assign 6] to restore
the controllers to their factory calibrations.
12.9.5.1. Wheels Calibration
Move the desired wheel to the specified position and press an Assign button to set that as
the calibration point for that wheel. To calibrate Pitch Wheel Center, return the Pitch wheel
to its resting position and then press [Assign 2].
12.9.5.2. Ribbon Calibration
•
Ribbon Min:
Touch the ribbon at its furthest position on the left and use [Assign 1]
to set that as the point that will produce the minimum modulation output value.
•
Ribbon Center:
Touch the ribbon in the middle and use [Assign 2] to set that as
the halfway point in its modulation range. This becomes the zero point between
positive and negative modulation for the
Relative and Scaled settings [p.93]
•
Ribbon Max:
Touch the ribbon at its furthest position on the right and use [Assign
3] to set that as the point that will produce the maximum modulation output
value.
12.9.5.3. Morphée Calibration
• Hold Morphée all the way down and press [Assign 1] to define the maximum Z
axis modulation point.
• Allow Morphée to return to its resting position, remove your hand, and press
[Assign 2] to define the minimum Z axis modulation point.
Arturia - User Manual PolyBrute - Settings
99
Summary of Contents for PolyBrute
Page 1: ...USER MANUAL...