6.3. 

Camera function

 

No 

item 

Setting 

range 

default   

value 

remarks 

Brightness 

-64

64 

adjust the brightness

 

contrast 

0

255 

128 

adjust the contrast 

Vividness 

0

255 

76 

adjust the saturation 

*1

 

sharpness 

0

Adjust sharpness correction 

gamma 

48

144 

(4 step) 

100 

Adjust gamma value 

γ

  = set value / 100, when set to 100 

γ

  = 1.00 

White balance 

2800

6500 

(100 step) 

5100 

(daylight 

white) 

Set the white balance by color temperature 

*2

 

auto white balance 

ON/OFF 

OFF 

Automatic white balance adjustment 

gain 

32

255 

32 

Sets the sensor gain 

Gain is set value x 0.03125 

Exposure 

  (exposure time) 

-13

-1 

1~5001 

*3

 

-7 

80 

*3

 

Sets the sensor exposure time 

10 

Automatic exposure 

adjustment 

ON/OFF 

OFF 

Adjust exposure time automatically 

Default target luminance value is 84 in 8bit value 

11 

Low light correction 

ON/OFF 

OFF 

It is an ON/OFF switching function for external IO, 

and it is possible to turn ON/OFF LEDs, etc. (option) 

 

*1 Saturation sets the gain value for Cb and Cr of the YCbCr signal. The gain is set value x 0.03125, 

32 x 0.03125 = 1.00 [times] when the setting value is 32, and 76 x 0.03125 = 2.375 times when the setting 

value is 76 (default). 

 

*2 White balance is adjusted with our default optical system, and may not be fully adjusted depending on 

the  combination  of  lenses  and  filters.  In  that  case,  customization  is  also  possible,  so  please  contact  us 

individually.  Also,  when  the  auto  white  balance  is  turned  on,  the  white  balance  is  constantly  adjusted  in 

response to changes in the screen, but it is not possible with normal software to fix the settings adjusted by 

the auto white balance. 

In this case, software customization is required, so please contact us individually. 

 

*3 Exposure time is set to "2 to the power of the set value [seconds]" when set in the Windows standard 

properties.  For  example,  a  setting  of  -7  (the  default)  gives  an  exposure  time  of  2^(-7)  =  1/128  seconds 

(approximately 7.81 milliseconds). 

Otherwise, it will be set in units of approximately 100 microseconds. 

For  example,  if  the  setting  value  is  80  (default  value),  the  exposure  time  will  be  80  *  100  =  8000[

μ

sec] 

(about 8 milliseconds) 

If the exposure time exceeds the default 1 frame time, the frame rate will be reduced. 

 

*4 For monochrome type, brightness, contrast, vividness, sharpness, gamma, and white balance settings are 

ignored. Only the settings of exposure time, gain, and low light compensation (external IO) are valid. 

In addition, if you have any questions about settings or individual customization, please contact us. 

Summary of Contents for ARTCAM-0134ARMINI-BW-UVC-OP

Page 1: ...1 August 9 2022 Ver1 00 USB2 0 CMOS CAMERA SMALL TYPE ARTCAM 0134AR UVC Series INSTRUCTION BOOKLET 1 2M pixels ARTCAM 0134ARSS UVC Series 1 2M pixels ARTCAM 0134ARMINI UVC Series ARTRAY CO LTD...

Page 2: ...6 6 Frame rate setting 12 7 Dimensions 13 7 1 ARTCAM 0134ARSS UVC 0134ARSS BW UVC 13 7 2 ARTCAM 0134ARSS UVC OP 0134ARSS BW UVC OP 14 7 3 ARTCAM 0134ARSS UVC OP CM 0134ARSS BW UVC OP CM 14 7 4 ARTCAM...

Page 3: ...ed 8 Please contact us if you find any unclear points or mistakes in this manual 9 Quoting copying or altering some or all parts of the manual without our permission is prohibited 10 We are not respon...

Page 4: ...temperature places such as inside of vehicles or under direct sunlight High temperature may cause damages to the camera or even cause fires Do not cover the product with cloth or other materials The p...

Page 5: ...nd regulations before actually exporting this product Guarantee To save the environment we do not issue warranty in printed format Instead all records of the warranty periods delivery dates and the cu...

Page 6: ...ompatible with UVC you can use it immediately without installing a driver just by connecting the USB cable to a PC or the like Supports global shutter Since the shutter method of the adopted CMOS sens...

Page 7: ...n used on smartphones tablets etc Connect a commercially available USB OTG compatible conversion cable etc to a smartphone etc and connect the USB A Type receptacle terminal to the included USB 2 0 ca...

Page 8: ...a USB hub with a USB OTG compatible cable and a USB A B cable then connect the USB hub and camera with the included USB 2 0 cable In this configuration when charging the smartphone side the HUB and sm...

Page 9: ...transfer USB Video Class 1 1 compliant Synchronization System Internal Synchronization Lens Mount C Mount 0134ARSS UVC 0134ARSS UVC OP CM Board lens Mount M12 P0 5 0134ARSS UVC OP Board lens Mount M1...

Page 10: ...compliant Synchronization System Internal Synchronization Lens Mount C Mount 0134ARSS BW UVC 0134ARSS BW UVC OP CM Board lens Mount M12 P0 5 0134ARSS BW UVC OP Board lens Mount M12 P0 5 Power DC5V Su...

Page 11: ...t 2 White balance is adjusted with our default optical system and may not be fully adjusted depending on the combination of lenses and filters In that case customization is also possible so please con...

Page 12: ...itched by software For monochrome cameras the upper 8 bit data is output only to the Y signal of YUV422 When displaying in RGB space RGB output values may differ due to YUV RGB conversion 6 6 Frame ra...

Page 13: ...13 7 Dimensions 7 1 ARTCAM 0134ARSS UVC 0134ARSS BW UVC...

Page 14: ...14 7 2 ARTCAM 0134ARSS UVC OP 0134ARSS BW UVC OP 7 3 ARTCAM 0134ARSS UVC OP CM 0134ARSS BW UVC OP CM...

Page 15: ...15 7 4 ARTCAM 0134ARMINI UVC 0134ARMINI BW UVC...

Page 16: ...16 8 Spectral Sensitivity Characteristics 8 1 ARTCAM 0134ARSS UVC 0134ARMINI UVC Color model 8 2 ARTCAM 0134ARSS BW UVC 0134ARMINI BW UVC Monochrome Model...

Page 17: ...t UVC such as Linux and Android can be used Please refer to Supported Platforms below Caution Please refer the restrictions below when you use ARTCAM series 1 Recommended System Requirements If the sy...

Page 18: ...18 ARTRAY CO LTD Obtained ISO 9001 2015 2018 9 17 1 17 5 Kouenjikita Suginami ku Tokyo 166 0002 Japan Tel 81 3 3389 5488 Fax 81 3 3389 5486 Email sales artray us URL www artray us...

Reviews: