Publication No. 980938 Rev. K
Model T940 User Manual
Astronics Test Systems
Soft Front Panel Operation 5-65
Figure 5-33: Configure UR14 Channel Properties Panel
Compare Input (V)
This control sets the comparator level of the selected channel group.
Min: 0.0
Max: 20.0
The relevant VXI
plug&play
API function is:
•
tat964_setUtilitySenseLevel
OC Detect (A)
This allows the user to set the over-current threshold of the selected channel
group.
The detect level can be set from 0.0 A to 1 A in increments of 62.5 mA.
The relevant VXI
plug&play
API function is:
•
tat964_setUtilitySourceParameter
All Channels
Sets the compare input and OC detect levels of all four channel groups to the
current panel settings.
The relevant VXI
plug&play
API functions are:
•
tat964_setUtilitySenseLevel
•
tat964_setUtilitySourceParameter
Configuring the AUX Channels
Access this panel from the menu bar:
Config > AUX Outputs
.