ARTHUR HOLM AHDV01 User Manual Download Page 1

   

 

 

 

 

 
 

User’s manual  

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
__________________________________________________ 

 

AHDV01 

Motorised wall mount for video conference cameras. 

Summary of Contents for AHDV01

Page 1: ...User s manual __________________________________________________ AHDV01 Motorised wall mount for video conference cameras ...

Page 2: ...nology is a part of the interior design as well as being used as a communication tool Please read this installation and operating instructions carefully and keep them in a safe place for a future consultation We remain at your entire disposal if you have any suggestions that would help us to improve our products Henrik Holm General Manager ...

Page 3: ...3 Table of contents EC REGULATIONS AND SECURITY 4 SAFETY INSTRUCTIONS 5 APPLICATIONS 6 FEATURES 6 IN BOX ELEMENTS 7 INSTALLATION 8 CONNECTION 10 CONTROLS 11 AHNET PROTOCOL 12 PRODUCT WARRANTY 14 ...

Page 4: ...rous un insulated voltages inside some of the components of sufficient magnitude to expose people to risk of electronic shock This symbol calls attention to important use and maintenance instructions in the manual that accompanies the unit This symbol indicates that the equipment conforms to the norms established by European community ...

Page 5: ...rd Wiring connected to hazardous voltage components requires installation by instructed person or the use of flexible cables ready For your security your equipment must be connected to an electrical outlet with grounding connection protection The electrical outlet must be operating in an easily access place ENVIRONMENT Install the system on a high and flat surface Install the system in a ventilate...

Page 6: ...ront enclosure is moved vertically unveiling the camera while the tray is simultaneously extracted This product range is specially designed for desk integration at Conference rooms Meeting rooms Auditorium Training rooms Managing rooms Information desk Features Control up down by external contact closure GPI remote control or AHNet Low power consumption Electronic engine control with different spe...

Page 7: ... installation of your retractable system please check the contents of the shipping carton it must contain the following items Motorised lift system Power cord User s Manual Power supply 100 240Vac 50 60Hz Output 12V Remote control ...

Page 8: ...gned for mounting on wall Installation is extremely simple Attach the enclosure into the hole previously made Use suitable hardware in the 4 holes Once system connections are done match front to enclosure matching pressure staples press until they are subject ...

Page 9: ...e Attach the video conferencing camera to platform with most appropriate screws under the camera model If in doubt ask the manufacturer of the video conference camera Push control button on remote control to lift the cover up DynamicVision will open the cover and move the tray horizontally outward Place the platform with the camera already fixed and connected recommended in the DynamicVision movab...

Page 10: ...Termination Active ON the termination ONLY on the last monitor of the RS422 bus GPI Monitor external contact close control SubD9 female 1 GPI1 2 GPI1 3 GPI2 4 GPI2 5 GPI3 6 GPI3 7 N C 8 12Vdc 600mA max 9 Ground Use GPI1 1 12Vdc 2 Ground to open the equipment Use GPI3 6 12Vdc 5 Ground to close the equipment Changing the monitor address Push OK One BEEP sounds Change the monitor address using UP or ...

Page 11: ...camera performs a forward motion Make sure that nothing obstructs its trajectory too Push to close the front cover Please make sure that nothing obstructs vertical down movement path While the cover moves downward covering the video conference camera the tray that supports it makes a horizontal movement that retracts video conference camera into the enclosure Make sure that nothing obstructs its t...

Page 12: ... answer Pins 3 6 the units receive orders Protocol to control the monitor by addressable RS422 bus You can connect up to 30 monitors on the same RS422 bus You can use a AH Interface Ethernet to control the RS422 bus The units should have set address and the address must start by 1 Maximum cable length between ends 500m AHnet Protocol Using 5 bytes to communication BYTE 0 START BYTE BYTE 1 ADDRESS ...

Page 13: ...Number of the monitor address Up to 30 monitors for each RS422 BUS CB1 Response in 8 bites of the monitor status CB2 Response in 8 bites of the monitor status CB1 BITE 7 6 5 4 3 2 1 0 CLOSED 1 1 0 1 OPENED 0 1 0 1 PROTECTION STOP 1 EQUIPMENT OK 0 To send an order to all the monitors you must use the address 249 Dec Byte1 F9 Hex Byte1 In this case the units do not respond ...

Page 14: ... your dealer or supplier for further information Information on Disposal in other Countries outside the European Union This symbol is only valid in the European Union If you wish to discard this product please contact your local authorities or dealer and ask for the correct method of disposal Product Warranty CONDITIONS OF WARRANTY Albiral Display Solutions S L with this document guarantees Tradem...

Page 15: ...Solutions S L Although Albiral Display Solutions S L pays for transport and insurance cost Albiral Display Solutions S L will not be responsible for the damages caused by transport if the customer does not inform in writing when receiving the goods b After this period of warranty Both freight and insurance costs will be paid by the customer 5 Albiral Display Solutions S L will not be responsible f...

Page 16: ...Hipòlit de Voltregà 08512 Barcelona Spain tel 34 93 850 23 76 23 83 fax 34 93 850 25 50 web www arthurholm com e mail marketing arthurholm com This manual can be modified without previous notice Arthur Holm is a registered brand by Albiral Display Solutions SL ...