background image

Installation and operation manual

DPC200-AC 

DIFFERENTIAL PRESSURE CONTROLLER

Low pressure with PI-control-mode

Doc.-no.: DPC200-AC_01_UK

Issue: 07/2019

Summary of Contents for DPC200-AC

Page 1: ...Installation and operation manual DPC200 AC DIFFERENTIAL PRESSURE CONTROLLER Low pressure with PI control mode Doc no DPC200 AC_01_UK Issue 07 2019 ...

Page 2: ...e de www sensor store de 07 2019 DPC200 AC_001_EN This documentation including all parts is protected by copyright Any utili sation or modification other than permissible under the strict limitations of copyright law is prohibited and liable to prosecution without the approval of the Arthur Grillo GmbH This applies in particular to duplications trans lations microfilming and storage and processing...

Page 3: ...ensions 3 2 Wall mounting 4 Start up 4 1 Overview DPC200 AC 4 2 Schematic view inside 4 3 Pressure connections 4 4 Electrical connection 4 5 Zero adjustment 5 Operation 5 1 Start menu 5 2 Menu structure 5 3 Measuring mode 5 4 Control mode 5 5 Adjustable parameters 5 6 Threshold calculation 5 7 Function alarm output 6 Maintenance 7 Warranty 8 Troubleshooting 9 Disposal 10 Specifications 10 1 CE lab...

Page 4: ...erial damage or minor or moderate bodily injuries CAUTION 1 2 Used pictograms and symbols In this manual the following symbols are used General hazard symbol dan ger warning caution Signal word for important information regarding the product which needs to be specifically pointed out NOTICE Hazard word Type of hazard Hazard source Hazard prevention 1 3 General notes This manual contains informatio...

Page 5: ...der the influence of the differential pressure the diaphragm displaces a measuring spring until the spring force compensates for the pressure pushing on the diaphragm A contactless differential transformer and suitable electronics convert this displacement into a continuously variable output voltage signal The DPC200 AC provides two function options 1 On the one hand it is used as a measuring devi...

Page 6: ...aterial damage Read the manual carefully before installation and operation Only experienced stuff may connect the device and bring it into operation CAUTION 3 1 Dimensions All dimensions in mm ø6 ø5 M16x1 5 4 5 104 54 95 70 The device is position depended The DPC200 AC must be mounted vertically NOTICE 3 2 Wall mounting 1 Hold the DPC200 AC against the wall Mark the mounting holes 2 Drill mounting...

Page 7: ...r 2 Cable gland 3 Pressure connection 1 4 Pressure connection 2 5 Cable gland 1 2 3 4 5 4 2 Schematic view inside Button T1 and T2 serve for the operation of the menu 4 3 Pressure connections Connect all pressure connections properly with plastic tubing inner diameter 5 or 6mm ButtonT1 ButtonT2 ...

Page 8: ...fset can be zeroed from the outside with a small bar magnet Do not use buttons T1 or T2 Adjustment Remove the tubing from the pressure connections Hold the bar magnet N S as shown here to the zero point adjustment for a short period of time to activate an internal reed switch The new zero point will be displayed and stored 5 Operation 5 1 Start menu For operating the menu unscrew the front cover t...

Page 9: ...9 Doc no DPC200 AC_01_EN Issue 07 2019 OPERATION 5 2 Menu structure ...

Page 10: ...xt menu item If selected parameter diff pressure limit switch 150 Pa Button T1 reset value Button T2 set value Button T1 confirm value display flashes once Press button T2 to get to the next menu item back and confirm Press button T1 to leave the menu Press button T2 to stay in the menu If selected parameter volume flow than follows the additional input for the k factor fan k factor k 70 Button T1...

Page 11: ...on T1 confirm value display flashes once Press button T2 to get to the next menu item setpoint 2 250 Pa Button T1 reset value Button T2 set value Button T1 confirm value display flashes once Press button T2 to get to the next menu item output voltage U 10 0V DC Button T1 reset value Button T2 set value Button T1 confirm value display flashes once Press button T2 to get to the next menu item P para...

Page 12: ... k 10 000 Vmax 632 456 m3 h Measuring range 6000 Pa k 10 000 Vmax 774 597 m3 h K 70 Limit values Differential pressure from 0 up to 100 of measuring range Volume flow from 0 5 up to 100 of measuring range k factor is considered OFF Nominal values setpoints Differential pressure from 0 up to 100 of measuring range Volume flow from 0 5 up to 100 of measuring range k factor is considered placeholder ...

Page 13: ...on the operating mode the function is different At the alarm event a contact between terminal no 7 and no 8 gets low resistive and can be loaded with a maximum of 30V DC 30 mA When the alarm is switched off the contact will be high resistive During alarm state in the control mode measuring mode an exclamation point is displayed 2nd line 16th character Control mode In order to recognize the limits ...

Page 14: ... the device beyond the intended use Disasters due to external influences and force majeure 8 Troubleshooting 9 Disposal Dispose of parts so as not to endanger the human health or environment Follow the laws in the country of use for disposing of electronic components and devices during disposal Description Activity Display does not show anything Check electrical connection Measurement stays zero F...

Page 15: ...000 Pa 0 2 bar max 0 2 bar tubing 5 mm ø or 6 mm ø UL 94 HB Case polyamid cover ABS cable inlet M16x1 5 screw terminal Electronic protection against reversed polarization 90 260 Vac 50 60 Hz 0 10 V Imax 1 mA Rmin 10 kOhm Open Collector max 30 V 30 mA LCD Display 2 x16 characters Measuring mode or controlling mode PI 2 setpoints adjustable within software Setpoints are selectable with floating cont...

Page 16: ...6 03 correction 1 2011 06 Electromagnetic compatibility EMC Part 6 2 Generic standards Immunity for industrial environments DIN EN 61000 6 3 2011 09 Electromagnetic compatibility EMC Part 6 3 Generic standards Emission standard for residential commer cial and light industrial environments You can order the Declaration of Conformity at Arthur Grillo GmbH Am Sandbach 7 40878 Ratingen Phone 0 21 02 4...

Reviews: