2.2.1

Critical Temperature Spot

During the safety qualification of this board, the location shown in the figure below was 
identified as a critical temperature spot. To guarantee proper board operation and  ensure 
safety, make sure that the temperature at the specified location is not exceeded. If not stated 
otherwise, the temperature should be measured by placing a sensor at the critical temperature 
spot.

Figure 2-1

Critical Temperature Spot

Summary of Contents for RTM-ATCA-9305 IO

Page 1: ...RTM ATCA 9305 IO Installation and Use P N 10010926 05 September 2015...

Page 2: ...anges from time to time in the content hereof without obligation of Artesyn to notify any person of such revision or changes Electronic versions of this material may be read online downloaded for pers...

Page 3: ...ng and Inspecting the Board 29 2 2 Environmental Requirements 29 2 2 1 Critical Temperature Spot 31 2 3 Power Requirements 32 2 4 Installing and Removing the RTM 32 2 4 1 Installing the RTM 32 2 4 1 1...

Page 4: ...ch 55 4 3 10 Gigabit Ethernet Transceiver 55 4 4 Module Management Controller 55 4 5 Serial Debug Port 56 4 6 SIPL Protocol 57 4 7 Artesyn OEM Commands 57 4 7 1 I2C Read SFP Register 58 4 7 2 I2C Writ...

Page 5: ...t Assignments 45 Table 3 2 Mezzanine Board Port Assignments 46 Table 3 3 Configuration 1 Interfaces 47 Table 3 4 Configuration 2 Interfaces 48 Table 3 5 SFP Connectors Pin Assignments 48 Table 3 6 SFP...

Page 6: ...RTM ATCA 9305 IO Installation and Use 10010926 05 6 List of Tables...

Page 7: ...e 2 1 Critical Temperature Spot 31 Figure 3 1 Main Board Layout 43 Figure 3 2 Sub board Layout 44 Figure 3 3 Face Plate for Configuration 1 46 Figure 3 4 Face Plate for Configuration 2 47 Figure 4 1 B...

Page 8: ...RTM ATCA 9305 IO Installation and Use 10010926 05 8 List of Figures...

Page 9: ...Definition ATCA Advanced Telecommunications Computing Architecture CSA Canadian Standards Association EMC Electromagnetic Compatibility ETSI European Telecommunications Standards Institute FCC Feder...

Page 10: ...d offsets 0b0000 Same for binary numbers digits are 0 and 1 bold Used to emphasize a word Screen Usedforon screenoutputandcoderelatedelements or commands in body text Courier Bold Used to characterize...

Page 11: ...jury Indicates a hazardous situation which if not avoided may result in minor or moderate injury Indicates a property damage message No danger encountered Pay attention to important information Notati...

Page 12: ...10010926 03 June 2010 Updated IPMI specifications in Features and Module Management Controller sections Updated IPMI Sensors table Updated Artesyn OEM Commands section 10010926 04 May 2014 Re branded...

Page 13: ...our Artesyn representative The product has been designed to meet the standard industrial safety requirements It must not be used except in its specific area of office telecommunication industry and in...

Page 14: ...own expense Changes or modifications not expressly approved by Artesyn Embedded Technologies could void the user s authority to operate the equipment Board products are tested in a representative syst...

Page 15: ...ion and removal of the product can damage circuits or shorten their life Before touching the product make sure that your are working in an ESD safe environment or wear an ESD wrist strap or ESD shoes...

Page 16: ...s grounded at both ends SFP SFP Modules Personal Injury and Damage of the RTM and SFP SFP Modules Installing and using SFP SFP modules which are not fully certified and which do not meet all relevant...

Page 17: ...ender the SFP SFP module inoperable Only remove the optical plug when you are ready to connect a cable to the SFP SFP module When no cable is connected cover the port with an optical port plug Environ...

Page 18: ...RTM ATCA 9305 IO Installation and Use 10010926 05 Safety Notes 18...

Page 19: ...ie sich bitte an die f r Sie zust ndige Gesch ftsstelle von Artesyn Das Produkt erf llt die f r die Industrie geforderten Sicherheitsvorschriften und darf ausschlie lich f r Anwendungen in der Telekom...

Page 20: ...Recht das System zu betreiben zunichte machen Um die Einhaltung der oben genannten Richtlinien zu beweisen werden die Boards in Referenzsystemen getestet Wenn Sie das Board gem der Anleitung in ein Sy...

Page 21: ...sbau von Blades RTMs kann Schaltkreise besch digen oder ihre Lebensdauer verk rzen Bevor Sie Blades RTMs oder elektronische Komponenten ber hren vergewissern Sie sich da Sie in einem ESD gesch tzten B...

Page 22: ...m ssen abgeschirmte innerGeb udeVerkabelung Verdrahtung die an beiden Enden geerdet ist zu verwenden SFP SFP Modules Gefahr von Verletzungen sowie von Besch digung des RTMs und SFP SFP Modulen Die Ins...

Page 23: ...s 18 Gigabit Ethernet ports to the ATCA 9305 Configuration 2 C0010717 00 provides 12 Gigabit Ethernet ports and two 10 Gigabit Ethernet ports Both configurations have the following features Module man...

Page 24: ...EC The directive on waste electrical and electronic equipment WEEE Directive 2002 96 EC 1 3 Mechanical Data This section lists the physical dimensions and weight of the RTM CISPR 22 CISPR 24 EN 55022...

Page 25: ...RTM Variants Model Part Number Description C0010716 00 Eighteen 1 Gigabit SFP ports C0010717 00 Twelve 1 Gigabit SFP ports plus two 10 Gigabit SFP ports Table 1 4 SFP Module Type Part Number Descripti...

Page 26: ...TCA 9305 IO Installation and Use 10010926 05 26 1 5 Board Identification This section shows the product label and assembly number and indicates where the label is located on the product Figure 1 1 Loc...

Page 27: ...1 5 1 Assembly Number Table 1 6 Assemble Numbers Configuration Assembly Number Configuration 1 18 1 Gigabit SFP ports C0010716 00 Configuration 2 12 1 Gigabit SFP ports and two 10 Gigabit SFP ports C0...

Page 28: ...Introduction RTM ATCA 9305 IO Installation and Use 10010926 05 28...

Page 29: ...nvironmental Requirements Make sure that the board when operated in your particular system configuration meets the environmental requirements specified below Operating temperatures refer to the temper...

Page 30: ...syn internal environmental requirements 5 to95 non condensingaccording to Artesyn internal environmental requirements Vibration 0 1 g from 5 to 100 Hz and back to 5 Hz at a rate of 0 1 octave minute 5...

Page 31: ...ard the location shown in the figure below was identified as a critical temperature spot To guarantee proper board operation and ensure safety make sure that the temperature at the specified location...

Page 32: ...slot where the RTM is to be installed into the shelf s rear which must be the same as that of the front blade 2 Open the lower handle of the front blade to power down its payload Damage of RTM and Fr...

Page 33: ...ed down 4 Make sure that the top and bottom handles of the RTM are in an outward position by squeezing the lever and latch together 5 Insert the RTM into the shelf by placing the top and bottom edges...

Page 34: ...he front blade are closed 11 Close the lower handle of the front blade so that both payloads of the RTM and front blade are powered up The blue LEDs on both the front blade and RTM start flashing This...

Page 35: ...ke sure that the top and bottom handles of the RTM are in an outward position by squeezing the lever and latch together 3 Insert the RTM into the shelf by placing the top and bottom edges in the card...

Page 36: ...stalling the front blade see ATCA 9305 User s Manual 11 Close the handles of the front blade The blue LEDs on the front blade and the RTM start flashing This indicates that the front blade is informin...

Page 37: ...tch the lower handle outward by squeezing the lever and latch together and then turning the handle outward until you feel a resistance 2 Wait until the blue LEDs on the front blade and RTM are permane...

Page 38: ...applicable 5 Loosen the screws on the RTM face plate 6 Remove the RTM from the slot Data Loss Removing the product with the blue LED still blinking causes data loss Wait until the blue LED is permane...

Page 39: ...ch are not fully certified and which do not meet all relevant safety standards may damage the RTM and the SFP SFP modules and may lead to personal injury Only use and install SFP SFP modules which are...

Page 40: ...of your SFP SFP module may be slightly different compared to the latch shown in the figure above 3 Grasp the SFP SFP module and then carefully slide it out of the slot When inserting an SFP module mak...

Page 41: ...l port plug SFP SFP Module Damage The optical port plug protects the sensitive optical fibres against dirt and damage Dirt and damage can render the SFP SFP module inoperable Only remove the optical p...

Page 42: ...Hardware Preparation and Installation RTM ATCA 9305 IO Installation and Use 10010926 05 42...

Page 43: ...Chapter 3 RTM ATCA 9305 IO Installation and Use 10010926 05 43 LEDs and I O Interfaces 3 1 Main Board Layout Figure 3 1 Main Board Layout...

Page 44: ...LEDs and I O Interfaces RTM ATCA 9305 IO Installation and Use 10010926 05 44 3 2 Sub board Layout Figure 3 2 Sub board Layout...

Page 45: ...n Board Port Assignments Location Function P1 Connects to J33 on ATCA 9305 P7 Connects to J31 on ATCA 9305 U171 BCM8725 Dual 10Gb PHY p Connects to the XAUI ports on ATCA 9305 p P8 Connects to J30 on...

Page 46: ...te Table 3 2 Mezzanine Board Port Assignments Location Function P1 to P12 SFP ports These ports provide 1 Gigabit Ethernet connection P13 P14 SFP ports These ports provide 10 Gigabit Ethernet connecti...

Page 47: ...vice LED 2 In Service LED RP COM This is a mini USB port that can be used to monitor the RTM Connected to the IPMI controller of RTM HOST COM This is mini USB port that can be used to monitor the fron...

Page 48: ...Out of Service LED 2 In Service LED RP COM This is a mini USB port that can be used to monitor the RTM SFP LED See Status LEDs HOST COM This is mini USB port that can be used to monitor the front bla...

Page 49: ...eeR Receiver Ground 151 VccR Receiver Power 161 VccT Transmitter Power 171 VeeT Transmitter Ground 181 TD Transmitter Data 19 TD Inverse Transmitter Data 20 VeeT Transmitter Ground Table 3 6 SFP Pin A...

Page 50: ...a 14 VeeR Receiver signal ground 15 VccR Receiver power 16 VccT Transmitter power 17 VeeT Transmitter signal ground 18 TD Transmitter data 19 TD Transmitter data inverted 20 VeeT Transmitter signal gr...

Page 51: ...9 Table 3 7 Host RP COM Pin Assignments P3 P2 continued Pin Signal Name Signal Description Table 3 8 SFP LED CR39 and CR40 LED Color Status Signal Description Green ON Normal operation OFF TX_FAULT d...

Page 52: ...LEDs and I O Interfaces RTM ATCA 9305 IO Installation and Use 10010926 05 52...

Page 53: ...and Use 10010926 05 53 Functional Description This chapter describes the functional blocks of the RTM 4 1 Block Diagram The following figures show the main functional blocks of the RTM Figure 4 1 Blo...

Page 54: ...Functional Description RTM ATCA 9305 IO Installation and Use 10010926 05 54 Figure 4 2 Block Diagram for Configuration 2 12 SFPs and 2 SFP...

Page 55: ...ront blade switch This allows the RTM to provide two 10 Gb SFP I O ports on the RTM face plate The default application of this transceiver is set to LAN 4 4 Module Management Controller The RTM provid...

Page 56: ...s in SIPL protocol 3 3V PP Voltage 0x21 2 5V PP Voltage 0x22 INLET temp RTM Temperature 0x23 OUTLET temp RTM Temperature 0x24 Switch Temp Temperature 0x25 1 8V PP Voltage 0x26 1 2V PP Note Thissensori...

Page 57: ...ed optionally by a space as shown in the following examples 18 00 22 lt newline gt 180022 lt newline gt The IPMC does not however support SIPL ASCII text commands as defined by the IPMI specification...

Page 58: ...e the level translator so that the MMC can access the SFP and other registers Type Byte Data Field Request Data 1 port SFP port to read 2 I2C address I2C address of SFP to read 3 register offset SFP r...

Page 59: ...tional Description RTM ATCA 9305 IO Installation and Use 10010926 05 59 4 7 4 Un Drive EEPROM This command can be used to disable the level translator Type Byte Data Field Response Data 1 Completion C...

Page 60: ...Functional Description RTM ATCA 9305 IO Installation and Use 10010926 05 60...

Page 61: ...t the type of document you are looking for 4 In the Search text box type the product name and click GO A 2 Related Specifications For additional information refer to the following table for related sp...

Page 62: ...Related Documentation RTM ATCA 9305 IO Installation and Use 10010926 05 62...

Page 63: ......

Page 64: ...syn and the Artesyn Embedded Technologies logo are trademarks and service marks of Artesyn Embedded Technologies Inc All other product or service names are the property of their respective owners 2015...

Reviews: