Software Configuration
MC1600 Extreme Edge Server Installation and Use (6806870A02A)
87
5.2.1.2
Firmware Upgrade
5.2.1.2.1
BMC Upgrade
The BMC can be upgraded using ipmitool over LAN as shown below:
NOTE: BMC default front panel Ethernet IP address is 192.168.201.9
1. Set your IP address on CPU1 or external server, to the same subnet as BMC.
(192.168.201.xxx)
2. Download hpm.1 image to CPU1 or external server and execute the following command:
ipmitool –I lanplus –H 192.168.201.9 –z 0x7fff –U admin –P admin
hpm upgrade <image name>
Figure 5-2
Dual CPU Variant
CPU 1
xlink = 172.27.1.10
ETH1 = 172.26.1.10
bcm = not configured by default
CPU 2
xlink = DHCP
ETH2 = 172.26.1.20
bcm = not configured by default
xlink interface
Broadcom Switch
bcm interface
bcm interface
ETH1
Front
Panel
ETH2
Front
Panel