Software Configuration
MC1600 Extreme Edge Server Installation and Use (6806870A02A)
107
5.2.2.1.5
Fan Control
The chassis fans run in the autonomous mode or the manual control mode and are
configurable via the Set Fan Speed Control command. When the fans are in the autonomous
mode, the fan control speed is determined by the aggregated temperature level and the
selected fan speed profile.Since only one cooling domain (cooling zone) is supported, one
setting is applied to all operating fans. Note that at low temperatures the system may turn off
some or all fans.
5.2.2.1.6
FRU Present State
There are two versions of the Get FRU Present State command. As shown in
, the command also returns the manufacturer’s IANA number, Product
ID, and the device revision. Such information may not be available if either the FRU does not
provide the information or the FRU is in such a state that it cannot provide the information to
the BMC. In either case, zeros are returned.
Table 5-10 Get Aggregated Temperature Sensor
Request Data
1
0xae
2
Version
Write as 0
3
FRU Device ID
1: the PCIe card
Other values are reserved
Response Data
1
Completion Code
2
0xae
3
Aggregated Temperature Level
0xFF: Aggregated Temperature Sensor disabled
Other values
[7]: invalid flag
0: temperature in [5:0] is valid
1: temperature in [5:0] is invalid
[6]: write as 0
[5:0] aggregated temperature level
Summary of Contents for MaxCore MC1600
Page 1: ...MaxCore MC1600 Extreme Edge Server Installation and Use 6806870A02A April 2019...
Page 8: ...List of Figures 6 MC1600 Extreme Edge Server Installation and Use 6806870A02A...
Page 26: ...Safety Notes 24 MaxCore MC1600 Extreme Edge Server Safety Notes Summary 6806870A04A...
Page 36: ...Sicherheitshinweise 34 MaxCore MC1600 Extreme Edge Server Safety Notes Summary 6806870A04A...
Page 116: ...Related Documentation 114 MC1600 Extreme Edge Server Installation and Use 6806870A02A...
Page 117: ......