Site Preparation
AXP640 Installation and Use (6806800M24F
)
82
3.2.3.1
Environmental Requirements
To ensure proper function of the system, make sure that the environment in which the system
is to be used fulfills the environmental requirements.
The environmental values must be tested and proven in the planned system configuration,
that is, the delivered system and other third-party products you want to integrate.
The following table lists the environmental requirements.
Operating temperatures refer to the temperature of the air circulating at the air intake of
the system and not to component temperatures.
Some of the climatic values may exceed the specification of some system components
(for example, hard disks). As Artesyn Embedded Technologies cannot guarantee the
functionality of third party products that are handled or operated out of their
specifications, the environmental conditions may be limited to the specifications of
these components.
Table 3-1 Environmental Conditions
Feature
Operating
Non-Operating (packed state)
Temperature
+5ºC (41°F) to +40ºC (104°F) (normal
operation) according to NEBS standard
GR-63-CORE
-5°C (23°F) to +55°C (131°F) (exceptional
operation) according to NEBS standard
GR-63-CORE
-40°C (-40°F) to +70°C (158°F)
Temp. change
+/-0.25°C/min
according to NEBS standard GR-63-CORE
+/-0.25°C/min
Relative
humidity
5% to 90% non-condensing
according to Artesyn Embedded
Technologies-internal environmental
requirements
5% to 95% non-condensing
according to Artesyn Embedded
Technologies-internal environmental
requirements
Shock
Half-sine, 11 ms, 30 m/s
2
Blade level packaging
Half-sine, 6 ms at 180 m/s
2
Summary of Contents for AXP640
Page 1: ...AXP640 Installation and Use P N 6806800M24F May 2014 ...
Page 8: ...AXP640 Installation and Use 6806800M24F Contents 8 Contents Contents ...
Page 10: ...AXP640 Installation and Use 6806800M24F 10 List of Tables ...
Page 50: ...Platform Architecture AXP640 Installation and Use 6806800M24F 50 ...
Page 70: ...AXP640 Shelf Description AXP640 Installation and Use 6806800M24F 70 Figure 2 14 AC Inlet 220V ...
Page 101: ...Site Preparation AXP640 Installation and Use 6806800M24F 101 Figure 3 13 Planning Checklist 2 ...
Page 102: ...Site Preparation AXP640 Installation and Use 6806800M24F 102 ...
Page 112: ...AXP640 Operations AXP640 Installation and Use 6806800M24F 112 ...
Page 136: ...AXP640 Shelf Installation AXP640 Installation and Use 6806800M24F 136 ...
Page 164: ...FRU Installation AXP640 Installation and Use 6806800M24F 164 ...
Page 186: ...Shelf Management Alarm Module AXP640 Installation and Use 6806800M24F 186 ...
Page 189: ......