Shelf Management Alarm Module
AXP640 Installation and Use (6806800M24F)
183
7.7
Hot Swap Interface
The SAM provides a hot swap interface allowing the SAM to be replaced without powering
down the shelf. The hot swap interface is implemented using the shelf manager mezzanine
CPLD device. The interface is composed of three components:
Screw activated faceplate switch
Presence signal indicating that the SAM is fully seated in its backplane connector
HS LED to indicate safe to remove state
7.8
Power
The SAM uses dual 48V power feeds, one from each PEM. Hot swap circuitry ensures correct
operation when a SAM is inserted into or removed from a live system.
5
Critical Alarm - NO
6
Critical Alarm - NC
7
Critical Alarm - COM
8
Minor Alarm - NO
9
Minor Alarm - NC
10
Minor Alarm - COM
11
Major Alarm - NO
12
Major Alarm - NC
13
Major Alarm - COM
14
Pwr Alarm - NO
15
Pwr Alarm - COM
Table 7-8 Hot Swap Interface Pin Out (continued)
Pin
Description
Summary of Contents for AXP640
Page 1: ...AXP640 Installation and Use P N 6806800M24F May 2014 ...
Page 8: ...AXP640 Installation and Use 6806800M24F Contents 8 Contents Contents ...
Page 10: ...AXP640 Installation and Use 6806800M24F 10 List of Tables ...
Page 50: ...Platform Architecture AXP640 Installation and Use 6806800M24F 50 ...
Page 70: ...AXP640 Shelf Description AXP640 Installation and Use 6806800M24F 70 Figure 2 14 AC Inlet 220V ...
Page 101: ...Site Preparation AXP640 Installation and Use 6806800M24F 101 Figure 3 13 Planning Checklist 2 ...
Page 102: ...Site Preparation AXP640 Installation and Use 6806800M24F 102 ...
Page 112: ...AXP640 Operations AXP640 Installation and Use 6806800M24F 112 ...
Page 136: ...AXP640 Shelf Installation AXP640 Installation and Use 6806800M24F 136 ...
Page 164: ...FRU Installation AXP640 Installation and Use 6806800M24F 164 ...
Page 186: ...Shelf Management Alarm Module AXP640 Installation and Use 6806800M24F 186 ...
Page 189: ......