AXP1440 Shelf Installation
98
AXP1440 Installation and Use (6806800H23U
)
Procedure - Power Up the System
Follow these steps to power up the system:
1. Push the PEM circuit breakers to the ON position.
2. Verify that all FRU LEDs illuminate and the PEM’s In Service LED is green.
The system executes its normal start-up routine and is then ready to use.
5.11 Accessing the System
You can access your system using the SAM shelf manager. The SAM-1500 direct serial console
connector (back of chassis) is an RJ-45 connector on the SAM face plate. This connector is
configured as DTE. The indirect serial console connector (front of chassis, located on the ADP)
is a 9-pin micro-D subconnector. For default user name and password, contact your Artesyn’s
sales representative.
Custom cables are required for these connectors. Refer to
RS-232 Serial Interface on page 132
for pin assignments.
5.12 Upgrading Firmware
Upgrading firmware on the AXP1440 shelf involves the following components:
IPMC firmware on the two Fan Tray Modules (FTMs)
IPMC firmware on the two Power Entry Modules (PEMs)
Shelf Manager firmware (including an FPGA image) on the two SAMs
5.12.1 FTM IPMC Firmware Upgrade
NOTE: The upgrade process described here uses a script named upgradeftm, which is
supplied on shelf managers starting with build 4.1.0-3.
There is a single IPMC firmware image common to the two FTMs in the AXP1440. The FTM
IPMCs are assigned IPMB addresses 0x56 and 0x58.
Summary of Contents for AXP1440
Page 1: ...AXP1440 Installation and Use P N 6806800H23U October 2018...
Page 8: ...6 AXP1440 Installation and Use 6806800H23U Contents...
Page 10: ...List of Figures 8 AXP1440 Installation and Use 6806800H23U...
Page 12: ...List of Tables 10 AXP1440 Installation and Use 6806800H23U...
Page 20: ...AXP1440 Installation and Use 6806800H23U About this Manual 18 About this Manual...
Page 79: ...Site Preparation AXP1440 Installation and Use 6806800H23U 77 Figure 3 4 Planning Checklist 2...
Page 80: ...Site Preparation 78 AXP1440 Installation and Use 6806800H23U...
Page 108: ...AXP1440 Shelf Installation 106 AXP1440 Installation and Use 6806800H23U...
Page 152: ...Shelf Management Alarm Module 150 AXP1440 Installation and Use 6806800H23U...
Page 155: ...1...