Supported IPMI Commands
ATCA-7480 Installation and Use (6806800T17A)
257
The following table provides the feature set supported with ATCA-7480:
8.3.2.2
Get Feature Configuration
This command can be used to get the state of feature configuration during IPMC runtime.
Table 8-25 Feature Selector Assignments
Feature Selector
Description
(3) 03h
Handle Debounce
(224) E0h
FAILSAFE Function Enable/Disable. For details, see
(225)E1h
FAIL PROTECT Function Enable/Disable. For details, see
Table 8-26 Get Feature Configuration Command
Byte Data
Field
Request Data
1
LSB of Artesyn IANA Enterprise Number. A value of CDh shall be
used.
2
2nd byte of Artesyn IANA Enterprise Number. A value of 65h
shall be used.
3
MSB of Artesyn IANA Enterprise Number. A value of 00h shall
be used.
4
Feature Selector, for details see table 3
Summary of Contents for ATCA-7480
Page 1: ...ATCA 7480 Installation and Use P N 6806800T17A February 2015...
Page 24: ...ATCA 7480 Installation and Use 6806800T17A About this Manual 24 About this Manual...
Page 30: ...ATCA 7480 Installation and Use 6806800T17A Safety Notes 30...
Page 36: ...ATCA 7480 Installation and Use 6806800T17A Sicherheitshinweise 36...
Page 42: ...Introduction ATCA 7480 Installation and Use 6806800T17A 42...
Page 64: ...Hardware Preparation and Installation ATCA 7480 Installation and Use 6806800T17A 64...
Page 82: ...Controls Indicators and Connectors ATCA 7480 Installation and Use 6806800T17A 82...
Page 98: ...Functional Description ATCA 7480 Installation and Use 6806800T17A 98...
Page 222: ...BIOS ATCA 7480 Installation and Use 6806800T17A 222...
Page 326: ...Replacing the Battery ATCA 7480 Installation and Use 6806800T17A 326...
Page 329: ......