Maps and Registers
ATCA-7360 Installation and Use (6806800J07S)
183
6.4.6
Serial Over LAN (SOL) Control Register
The IPMC software can route serial data from serial port 1 (COM1) or serial port 2 (COM2) to
the IPMC.
Table 6-43 Serial Redirection Control Register
Address Offset: 0x03
Bit
Description
Default
Access
0
COM1 used for serial redirection:
0: COM1 not used for serial redirection
1: COM1 used for serial redirection
0
LPC: r/w
IPMC: r
1
COM2 use for serial redirection
0: COM2 not used for serial redirection
1: COM2 used for serial redirection
0
LPC: r/w
IPMC: r
7:2
Reserved
0
r
When both control bits are enabled bit 1 is ignored.
Table 6-44 Serial over LAN Control Register
Address Offset: 0x04
Bit
Description
Default
Access
0
SOL over COM1 enable:
0: disabled
1: enabled. COM1 is forwarded to IMPC
PWR_GOOD: 0
LPC: r/w
IPMC: r
1
SOL over COM2 enable:
0: disabled
1: enabled. COM2 is forwarded to IMPC
PWR_GOOD: 0
LPC: r/w
IPMC: r
7:2
Reserved
0
r
Summary of Contents for ATCA-7360
Page 1: ...ATCA 7360 Installation and Use P N 6806800J07S May 2016...
Page 26: ...ATCA 7360 Installation and Use 6806800J07S About this Manual 26 About this Manual...
Page 36: ...ATCA 7360 Installation and Use 6806800J07S Sicherheitshinweise 36...
Page 43: ...Introduction ATCA 7360 Installation and Use 6806800J07S 43...
Page 44: ...Introduction ATCA 7360 Installation and Use 6806800J07S 44...
Page 66: ...Installation ATCA 7360 Installation and Use 6806800J07S 66...
Page 258: ...Supported IPMI Commands ATCA 7360 Installation and Use 6806800J07S 258...
Page 284: ...Replacing the Battery ATCA 7360 Installation and Use 6806800J07S 284...
Page 287: ......