Controls, Indicators and Connectors
Centellis 2000 User Card 10GE with Telco Alarm Installation and Use (6806800M46C
)
46
3.2
Sensors
The IPMC functionality is based on the IPMI specification V1.5.
The IPMI sensors on the Centellis 2000 User Card 10GE with Telco Alarm are shown in
For further information, refer
Centellis 2000 User Card 10 GE with Telco Alarm: Control via IPMI
Programmer’s Reference.
Table 3-3 Centellis 2000 User Card 10GE with Telco Alarm Specific Sensors
Sensor Name
Sensor Type Code
Description
Generate
Event
Event/ Reading Type
Code
HotSwap HotSwap (F0h)
Hot swap sensor Yes
Sensor specific (6Fh)
Ejector_State Button (14h)
Ejector state
sensor
-
Sensor specific (6Fh)
IPMC_State OEM (D5h)
IPMC state OEM
sensor
-
Sensor specific (6Fh)
IPMB0_State IPMB (F1h)
IPMB0 state
sensor
-
Sensor specific (6Fh)
SFP_Enable Other FRU (1Ah)
Enable/Disable
SFP Writable OEM
sensor
No
Type enable (9)
SFP_TXDIS Other FRU (1Ah)
SFP TXDIS signal
Yes
Reading type failure (4)
SFP_LOS Other FRU (1Ah)
Loss of signal
indication
Yes
Reading type failure (4)
SFP_TXFAULT Other FRU (1Ah)
SFP transmit fault Yes
Reading type failure (4)
SFP_PRESENT Other FRU (1Ah)
SFP presence
sensor
Yes
Presence (8)
PMD_LOSS_SIGNAL Monitor IC (26h) Loss of signal
indication
Yes
Reading type failure (4)
PMD_CMU_LOCK Monitor IC (26h)
PMD CMU Lock
detect
Yes
Reading type failure (4)
PMD_LinkAlarm Monitor IC (26h)
Loss of signal
indication
Yes
Reading Type failure (4)
PMD_CDR_LOCK Monitor IC (26h)
PMD CDR Lock
detect
Yes