Maps and Registers
132
ATCA-7540 Installation and Use (6806871A01A
)
5.1.11.1 ME Power Failure Registers
When an ME failure occurs, the red power failure LED (signal PWR_FAIL_) starts blinking. (The
LED is one second ON and one second OFF).
The error state is kept until ME wakes up (signal SLP_A_ becomes high).
The table below shows all possible failing states and their coding.
Table 5-44. ME Power Failure State Register
Address Offset: 0x08
Bit
Description
Default
Access
2:0
ME Power Failure State. Latched last ME state when
failure occurred. See
ME Power Failure
States.
Note: Only valid with ME Failure (Bit 7) set
PWR_GOOD:0
IPMC: r
6:3
Reserved
0
IPMC: r
7
ME Failure. ME state machine sampled a failing ME
Power status:
0: No ME Failure. Normal ME operation.
1: ME failure. ME failure detected.
PWR_GOOD:0
IPMC: r
Table 5-45. ME Power Failure States
State
Coding
State
Name
Description
0
ME_OFF
Timeout. ASW power good for more than 45ms also
ME is in ME_OFF state.
2
ME_ON
ASW power good lost
3
ME_PWR
Timeout. No ASW power good after 45 ms
4
ME_WAIT
ASW power good lost
5
ME_WAIT_OFF
ASW power good lost
Other
-
These values will never occur
Summary of Contents for ATCA-7540
Page 1: ...ATCA 7540 Installation and Use P N 6806871A01A December 2018 ...
Page 12: ...12 ATCA 7540 Installation and Use 6806871A01A Contents ...
Page 28: ...About this Manual 28 ATCA 7540 Installation and Use 6806871A01A ...
Page 34: ...Safety Notes 34 ATCA 7540 Installation and Use 6806871A01A ...
Page 66: ...Hardware Preparation and Installation 66 ATCA 7540 Installation and Use 6806871A01A ...
Page 276: ...Supported IPMI Commands 276 ATCA 7540 Installation and Use 6806871A01A ...
Page 322: ...Related Documentation 322 ATCA 7540 Installation and Use 6806871A01A ...
Page 323: ......