Artecta A9915045 Manual Download Page 4

 

  

 

 

   

 

Ordercode: A9915045

 

LED Dim 12 

IMPORTANT: 

The manufacturer will not accept liability for any resulting damages caused by the non-observance of 
this manual or any unauthorized modification to the device. 
 

 

Never let the power cord come into contact with other cables! Handle the power cord and all 
connections with the mains with particular caution! 

 

Never remove warning or informative labels from the device. 

 

Never use anything to cover the ground contact. 

 

Never leave any cables lying around. 

 

Do not open the device and do not modify the device. 

 

Do not connect this device to a dimmer pack. 

 

Do not switch the device on and off in short intervals, as this will reduce the device’s life. 

 

Do not shake the device. Avoid brute force when installing or operating the device. 

 

Only use the device indoors, avoid contact with water or other liquids. 

 

Only operate the device after having checked if the housing is firmly closed and all screws are tightly 
fastened. 

 

Only operate the device after having familiarized with its functions. 

 

Avoid flames and do not put close to flammable liquids or gases. 

 

Always keep the case closed while operating. 

 

Always allow a free air space of at least 50 cm around the device for ventilation. 

 

Always disconnect power from the mains, when device is not used or before cleaning! Only handle 
the power cord holding it by the plug. Never pull out the plug by tugging the power cord. 

 

Make sure that the device is not exposed to extreme heat, moisture or dust. 

 

Make sure that the available voltage is not higher than stated on the rear panel. 

 

Make sure that the power cord is never crimped or damaged. Check the device and the power 
cord from time to time. 

 

If device was dropped or struck, disconnect mains power supply immediately. Have a qualified 
engineer inspect for safety before operating. 

 

If the device has been exposed to drastic temperature fluctuation (e.g. after transportation), do not 
switch it on immediately. The arising condensation water might damage your device. Leave the 
device switched off until it has reached room temperature. 

 

If your Artecta device fails to work properly, discontinue the use immediately. Pack the device 
securely (preferably in the original packing material), and return it to your Artecta dealer for service. 

 

For adult use only. The device must be installed beyond the reach of children. Never leave the 
device running unattended. 

 

Never attempt to bypass the thermostatic switch or fuses. 

 

The user is responsible for correct positioning and operating of the LED Dim 12. The manufacturer will 
not accept liability for damages caused by the misuse or incorrect installation of this device. 

 

Repairs, servicing and electric connection must be carried out by a qualified technician. 

 

WARRANTY: Till one year after date of purchase. 

 

Operating Determinations 

 

This device is not designed for permanent operation. Consistent operation breaks will ensure that the 
device will serve you for a long time without defects. 

 

The maximum ambient temperature t

a

 = 40 °C must never be exceeded. 

 

The relative humidity must not exceed 50 % with an ambient temperature of 40 °C. 

 

If this device is operated in any other way than the one described in this manual, the product may 
suffer damages and the warranty becomes void. 

 

Any other operation may lead to dangers like short-circuit, burns, electric shock, crash, etc. 

 

You endanger your own safety and the safety of others! 

 
 

 

Summary of Contents for A9915045

Page 1: ...LED Dim 12 V1 Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands Ordercode A9915045 MANUAL ENGLISH...

Page 2: ...attern 12 1 1 2 Fadetime 12 1 1 3 Speed 12 1 2 Manual Mode 13 1 3 DMX Mode 14 1 3 1 Channel Modes 14 1 3 2 DMX Addressing 15 1 3 3 DMX Error 15 1 3 4 Glide 15 1 3 5 DMX Status 15 2 Load Color Modes 15...

Page 3: ...ox and packing Your shipment includes Artecta LED Dim 12 User manual Safety Instructions Every person involved with the installation operation and maintenance of this device has to be qualified follow...

Page 4: ...ever crimped or damaged Check the device and the power cord from time to time If device was dropped or struck disconnect mains power supply immediately Have a qualified engineer inspect for safety bef...

Page 5: ...UPS packing or double boxing is always a safe method to use Note If you are given an RMA number please include the following information on a piece of paper inside the box 01 Your name 02 Your addres...

Page 6: ...pply 12 24 V DC Load 12 V max 6 A channel 15 A total 180 W Load 24 V max 6 A channel 15 A total 360 W Housing Black powder coated metal DMX connections 3 pin XLR RJ45 IN OUT DMX channels 3 6 18 36 cha...

Page 7: ...OUT 08 3 pin DMX signal connector OUT Installation Remove all packing materials from the LED Dim 12 Check if all foam and plastic padding is removed Connect all cables Do not supply power before the w...

Page 8: ...DMX signal cable from the first device s DMX RJ45 out socket to the second device s in socket Repeat this process to link the second third and fourth devices 04 Connect LEDs to the LED connectors on...

Page 9: ...esses which is the first channel with which the LED Dim will respond to the controller Please note when you use the controller the device has 48 channels When using multiple LED Dims make sure you set...

Page 10: ...9 Ordercode A9915045 LED Dim 12 Menu Overview...

Page 11: ...10 Ordercode A9915045 LED Dim 12...

Page 12: ...n mode 01 While in main menu press the UP DOWN buttons until the display shows 02 Press the OK button to enter 03 Press the UP DOWN buttons to choose one of the 3 operation modes Auto mode Manual mode...

Page 13: ...confirm your choice 1 1 2 Fadetime I this menu you can set the fade time 01 Press the UP DOWN buttons until the display shows 02 Press the OK button to open the menu 03 Press the UP DOWN buttons to se...

Page 14: ...olors depends on the currently selected color mode LOAD There are 4 color modes RGB RGBW WHITE and WW CW For more information see 2 Load Color Modes page 15 02 Press the OK button to open the desired...

Page 15: ...he menu 03 Press the UP DOWN buttons to select the desired DMX channel mode Note The availability of the static colors depends on the currently selected color mode LOAD There are 4 color modes RGB RGB...

Page 16: ...oice 1 3 4 Glide In this menu you can activate deactivate the fade time 01 Press the UP DOWN buttons until the display shows 02 Press the OK button to open the menu 03 Press the UP DOWN buttons to sel...

Page 17: ...255 Gradual adjustment Red from dark to brightest Channel 5 Green Outputs 7 12 0 255 Gradual adjustment Green from dark to brightest Channel 6 Blue Outputs 7 12 0 255 Gradual adjustment Blue from dark...

Page 18: ...l adjustment Blue from dark to brightest Channel 16 Red Outputs 11 12 0 255 Gradual adjustment Red from dark to brightest Channel 17 Green Outputs 11 12 0 255 Gradual adjustment Green from dark to bri...

Page 19: ...en Outputs 1 12 0 255 Gradual adjustment Green from dark to brightest Channel 3 Blue Outputs 1 12 0 255 Gradual adjustment Blue from dark to brightest Channel 4 White Outputs 1 12 0 255 Gradual adjust...

Page 20: ...adjustment White from dark to brightest Channel 5 Red Outputs 3 4 0 255 Gradual adjustment Red from dark to brightest Channel 6 Green Outputs 3 4 0 255 Gradual adjustment Green from dark to brightest...

Page 21: ...al adjustment Red from dark to brightest Channel 6 Green Output 2 0 255 Gradual adjustment Green from dark to brightest Channel 7 Blue Output 2 0 255 Gradual adjustment Blue from dark to brightest Cha...

Page 22: ...to brightest Channel 3 White Outputs 5 6 0 255 Gradual adjustment White from dark to brightest Channel 4 White Outputs 7 8 0 255 Gradual adjustment White from dark to brightest Channel 5 White Output...

Page 23: ...m White from dark to brightest Channel 4 Cool White Outputs 7 12 0 255 Gradual adjustment Cool White from dark to brightest 12 channels WW CW Channel 1 Warm White Outputs 1 2 0 255 Gradual adjustment...

Page 24: ...year in the course of an acceptance test The operator has to make sure that safety related and machine technical installations are to be inspected by a skilled person once a year The following points...

Page 25: ...atically or not at all to the controller Poor data quality Check data quality If much lower than 100 percent the problem may be a bad data link connection poor quality or broken cables missing termina...

Page 26: ...nels RGB 4 8 24 48 channels RGBW 1 2 6 12 channels WHITE 2 4 12 24 channels WW CW 12 24V DC IN 4 pin Phoenix terminal maximum cable gauge 1 5 mm2 AWG 12 PWM OUT 4 pin Phoenix terminal maximum cable ga...

Page 27: ...26 Ordercode A9915045 LED Dim 12...

Page 28: ...2020 Artecta...

Reviews: