13
3-5 RS-232 interface
Flow control:
None-The communication only uses TxD and RxD signals without any hardware or software
handshaking protocol.
RTS/CTS- If the imager wants to send the barcode data to host computer, it will issue the RTS signal
first, wait for the CTS signal from the host computer, and then perform the normal data communication.
If there is no replied CTS signal from the host computer after the timeout duration, the imager will
issue an error indication. By setting (Host idle: Low RTS) or (Host idle: High RTS), the imager can be
set to match the Serial Host RTS line.
XON/XOFF- An XOFF character turns the imager transmission off until the imager receives an XON
character.
ACK/NAK- After transmitting data, the imager expects either an ACK (acknowledge) or NAK (not
acknowledge) response from the host. When a NAK is received, the imager transmits the same data
again and waits for either an ACK or NAK. After three unsuccessful attempts to send data when
NAKs are received, the imager issues an error indication and discards the data.
Inter-character delay: This delay is inserted after each data character transmitted.
Response delay: This delay is used for serial communication of the imager when it waits for a
handshaking acknowledgment from the host.
Multiple-scan setting
Single-scan setting
Option barcode
Option
Alpha. entry
Flow control
None
00*
*
RTS/CTS
(Host idle: Low RTS)
01
RTS/CTS
(Host idle: High RTS)
02
XON/XOFF
03
ACK/NAK
04
Inter-character delay
0 ms
00*
*
5 ms
01
10 ms
02
20 ms
03
40 ms
04
Summary of Contents for AS-2350
Page 1: ...AS 2350 Presentation Imager User Manual Version AS 2350_UM_EN_V1 1 3...
Page 2: ......
Page 4: ...ii...
Page 10: ...4 2 2 Dimensions...
Page 11: ...5 2 3 Parts of the imager Figure 2 2 Trigger Scan window Beeper...
Page 14: ...8 2 6 Field of view Figure 2 6 Field of view Figure 2 7 Field of view Front view...
Page 92: ...86 Aztec Code 12345678901234567890 Han Xin Code 12345678901234567890...