7-15
FlexiBowl - models 350 - 500 - 650 - 800
CHAPTER 7 - Maintenance
7.3.4 Replacing the shaker
REPLACING THE SHAKER
Operator qualification
Mechanical maintenance technician
PPE required
Tools/Products to be used
• Allen key
• Loctite 243
CAUTiOn!
Disconnect the power supply before taking the cover off.
Following a visual inspection, if the rubber mounts and screws in the top part of the cylinder are worn, the shaker must
be replaced. Proceed as follows to
replace the unit
:
Step
Action
Picture
1
Unplug the power cable from the control panel.
2
Take the cover off the FlexiBowl
®
.
3
Unscrew the two grub screws
(A)
so that the bar
(B)
can be removed.
A
A
4
Pull the bar out
(B)
.
B
5
Unscrew the screws
(C)
.
C
C
6
Remove the unit and replace it.
iMPORTAnT!
Always use LOCTITE 243 threadlocker to ensure the screws are properly secured.