7-5
FlexiBowl - models 350 - 500 - 650 - 800
CHAPTER 7 - Maintenance
7.2.1.2
Inspection of safety devices
Perform the following checks to
ensure that the safety devices work properly
:
Step
Action
1
Check that the machine covers are in place and fixed properly.
2
Check that the power cable is not damaged and/or worn.
7.2.1.3
Checking wear of the shaker
Proceed as follows to
check for wear of the shaker
:
Step
Action
Picture
1
Disconnect the power and air supply of the machine.
2
Take the cover off the FlexiBowl
®
.
3
Visually check for wear of the shaker.
7.2.1.4 Checking for wear of the relays
Visually check for wear of the relays.
There are: 3 static relays (that control the light, valve 1 and valve 2 respectively) and 1 mechanical relay (that controls the
“READY/FAULT” STATUS LED on the control panel).
When the “FAULT” STATUS LED is on and the FlexiBowl® works correctly, check the relay.
If this condition is not the one indicated above, connect to the FlexiBowl Parameters user interface program and press
Cmd SR. A window will be displayed containing any error messages.