![Arris ICX 7650-48P Configuration Manual Download Page 90](http://html1.mh-extra.com/html/arris/icx-7650-48p/icx-7650-48p_configuration-manual_2976303090.webp)
TABLE 19
ICX 7150 stacking capabilities (continued)
Stacking capability
ICX 7150
Additional information
Reconfigurable ports
Supported
Use the no stack-port command to
reconfigure one stack port as a data uplink
port.
Once licensed, stacking ports will come up
automatically as 10-Gbps.
You can manually reconfigure 1-Gbps ports to
licensed 10-Gbps ports and vice versa using
the speed-duplex command. Refer to Ruckus
FastIron Software Licensing Guide for
information.
Stack trunks
Supported
Refer to
on page
96.
ICX 7150-C12P devices do not support
stacking trunks.
Linear-topology trunks
ICX7150-24P: stack-trunk x/3/1 to x/3/4
ICX7150-48P: no linear-topology trunk
ICX7150-48ZP: stack-trunk x/2/1 to x/2/4
ICX7150-12C: stack-trunk x/3/1 to x/3/2
A linear-topology trunk is allowed only in a
two-unit stack. It places the ports from both
directions into one trunk.
Refer to
Support for two-unit stack linear-
on page 36 for more
information.
Hitless switchover and hitless failover
Supported
Refer to
on page 171.
License requirements
A 10-Gbps license is required to support
stacking, except on ICX 7150-48ZP devices.
Two 10-Gbps ports are standard on ICX
7150-48ZP devices, and any additional 10-
Gbps ports require a license. On other ICX
7150 models, all 10-Gbps ports require a
license.
Licenses are available for additional 10-Gbps
ports except on ICX 7150-C12P devices, which
has only two available ports. Refer to the
Ruckus FastIron Software Licensing Guide for
information.
Configuration options
Manual and automatic, including interactive-
setup and zero-touch provisioning
Refer to
56.
Access methods
TFTP, SCP
Software images, boot images, and signatures
can be downloaded to a stack using TFTP and
SCP. Refer to the Ruckus FastIron Software
Upgrade Guide for more information.
Stacking commands
All stacking CLI is available on the ICX 7150
unless otherwise noted on the command
reference page.
ICX 7150 stacking ports
Depending on the model, up to four SFP+ ports on the front panel of the ICX 7150 device support stacking. The ports can also be
used as uplink (data) ports. The following figures show the location and numbering for stacking ports. The numbering for the
ports is in three-tuple format (x/y/z) and refers to StackID/Slot/Port.
ICX 7150-C12P devices have two stacking ports on the front panel as shown in the following figure.
Stacking by Device
ICX 7150 stack configuration overview
Ruckus FastIron Stacking Configuration Guide, 08.0.90
90
Part Number: 53-1005572-01
Summary of Contents for ICX 7650-48P
Page 8: ...Ruckus FastIron Stacking Configuration Guide 08 0 90 8 Part Number 53 1005572 01...
Page 22: ...Ruckus FastIron Stacking Configuration Guide 08 0 90 22 Part Number 53 1005572 01...
Page 88: ...Ruckus FastIron Stacking Configuration Guide 08 0 90 88 Part Number 53 1005572 01...
Page 170: ...Ruckus FastIron Stacking Configuration Guide 08 0 90 170 Part Number 53 1005572 01...
Page 236: ...Ruckus FastIron Stacking Configuration Guide 08 0 90 236 Part Number 53 1005572 01...