Rev D
System Management Module 2 (SMM-2)
7-49
a. Type
configure
(to enter the CLI configuration mode).
b. Type
set CHPMAX5000-MIB chpMaxShelves chpAllow
.
c. At the admin@
smm-2_ip_address
% prompt, type
commit
3. From any PC, open a DOS command tool window (select
Start > Run
and type
cmd
)
to initiate an FTP command. Most systems have the function to FTP files from the
computer to another device on the Local Network. If FTP does not function on your
computer, contact your network administrator to have it turned on.
4. In the open DOS command window, use the cd command to get to the directory
where the files to be downloaded to the SMM-2 are located.
5. Type
ftp
command followed by the IP address of your SMM-2 module. The FTP
session will be established and ready to accept a new user name. The user name is
anonymous
, and the default password is
anonymous
.
6. Upgrading requires the binary mode to transfer files. In the FTP program, type
bin
to set the transfer mode to binary.
7. To put a file from the local PC directory you simply type in the command
put
followed by the file name that you want to transfer from the PC to the SMM-2.
8. The
requested file action successful
message indicates that the file has been
successfully transferred to the SMM-2’s file system. Once the file is in the SMM-2, the
upgrade is in process. The SMM-2 must be reset following completion of the
upgrade in order for the upgrade to take effect.
9. Return to the SMM-2 CLI by telnetting to smm2 and at the
admin@
smm-2_ip_address
% prompt, type
show CHPMAX5000-MIB
chpSlotStatusTable chpSlotStatusEntry 115 chpSlotStatusFWDownload
to
determine if the download was completed.
10. If completed, type
conf
to enter the configuration mode.
11. Reset the SMM-2 by typing
reboot
.
SMM-2 Specifications
Table 7.7 SMM-2 Specifications
Characteristic
Specification
Electrical
Power
2.5 W
Connectors
RS-485 (Shelf Interconnect)
38.4 kbps
RJ-45 Ethernet
10/100 Mbps
Serial Peripheral Interface Bus
4800 kbps
Summary of Contents for CHP Max5000
Page 2: ......
Page 12: ...x CHP Max Headend Optics Platform Chassis Controllers and Power Supplies 1508685 Rev D...
Page 100: ...4 18 CHP Max Headend Optics Platform Chassis Controllers and Power Supplies Rev D...
Page 120: ...5 20 CHP Max Headend Optics Platform Chassis Controllers and Power Supplies Rev D...
Page 199: ...Rev D System Management Module 2 SMM 2 7 33 Figure 7 28 Add CHPMax5000 Device Window...
Page 261: ...1508685 Rev D CHP Max Trap Information B 29...
Page 262: ...B 30 CHP Max Headend Optics Platform Chassis Controllers and Power Supplies 1508685 Rev D...
Page 266: ......