1508685 Rev D
CHP Max Element Management Modules CHP-CMM, CMM-1, SMM, and SMM-1
6-29
3. Right click on the Internal Temperature meter and select
Configure
from the shortcut
menu. Refer to Figure 6.19.
4. In the Alarm Setup area, drag the slider or enter the desired alarm limit value for the
Major low, Minor low, Minor high, and Major high. Click
OK
to save these alarm limit
values.
5. Right click on the +5 VDC meter and select
Configure
from the shortcut menu. Refer
to Figure 6.19 on page 6-29.
6. In the Alarm Setup area, drag the slider or enter the desired alarm limit value for the
Major low, Minor low, Minor high, and Major high. Click
OK
to save these alarm limit
values.
7. Repeat Steps 5 and 6 to the –5 VDC, +12 VDC, and +3.3 VDC meters if you want to
adjust these alarm threshold values.
Figure 6.19
Internal
Temperature and
+5V
DC
Threshold
Limits
Updating the CHP-CMM Microcontroller Firmware
Update CMM firmware through the CHP Max
Craft Management Software
using either of the
following two methods.
Method 1
➤
To update CMM microcontroller firmware
1. Obtain the appropriate firmware file through ARRIS technical support or your sales
representative. Use firmware file(s) listed in Table 6.5 to update the firmware in a
module.
+5V
DC
Alarm Threshold Settings
Internal Temperature Alarm Threshold Settings
Summary of Contents for CHP Max5000
Page 2: ......
Page 12: ...x CHP Max Headend Optics Platform Chassis Controllers and Power Supplies 1508685 Rev D...
Page 100: ...4 18 CHP Max Headend Optics Platform Chassis Controllers and Power Supplies Rev D...
Page 120: ...5 20 CHP Max Headend Optics Platform Chassis Controllers and Power Supplies Rev D...
Page 199: ...Rev D System Management Module 2 SMM 2 7 33 Figure 7 28 Add CHPMax5000 Device Window...
Page 261: ...1508685 Rev D CHP Max Trap Information B 29...
Page 262: ...B 30 CHP Max Headend Optics Platform Chassis Controllers and Power Supplies 1508685 Rev D...
Page 266: ......