6-2
CHP Max™ Headend Optics Platform Chassis, Controllers and Power Supplies
1508685 Rev D
Local Monitoring
A computer with
Craft Management Software
is used to monitor a single CHP Max5000 chassis
through a direct RS-232 connection to either the CMM or SMM controller module. The
controller module sends management signals through the serial peripheral interface (SPI)
bus on the chassis backplane to the other modules installed in the chassis, and status
information from the modules travels back through the same route. The controller module
then communicates with the computer running the
Craft Management Software
.
Auto Config
Auto Config (auto-configuration) refers to the management module in the shelf making
changes to the configurable settings of an application module without user intervention. For
example, when an application module in a shelf with an original CMM or SMM is replaced,
any changes made to the default alarm thresholds, optical output power, RF attenuator, etc.,
would be lost. The original CMM (P/N CHP-CMM) and SMM (P/N CHP-SMM) modules do not
support Auto Config on the 10 application module or the redundant power supplies in a
shelf.
In August 2006, ARRIS released the Auto Config version of CMM (P/N CHP-CMM-1) and SMM
(P/N CHP-SMM-1) modules. These new management modules contains a large flash memory
to store the configurable parameters such as alarm thresholds, optical output power, RF
attenuator, etc., based on slot location for each of the 10 application modules and power
supply(s). This Auto Config feature allows you to replace an Auto Config supported module
without cumbersome setup and the management module will automatically restore the
configurable parameters of the previously installed module. In order to use the Auto Config
feature, the following requirements must be met:
■
Auto Config management module (P/N CHP-CMM-1) must be installed
■
Auto Config for an individual shelf does not require the SMM-1 module
■
Do not attempt to install CMM-1 firmware onto a CMM module
■
Auto Config supported application modules listed in Table 6.1 must also be installed
Table 6.1 Auto Config Supported Application Modules
Application Module
CMM-1
Firmware
Revision*
SMM-2
Firmware
Revision
CHP-2RRX-xx
4.000
2.3.0.0
CHP-C2-MWXx
4.000
2.3.0.0
CHP-C2-MWVx
4.000
2.3.0.0
CHP-FTX
-
2.3.0.0
CHP-GAMP3
4.000
2.3.0.0
CHP-GFX-D-xx-S/AF
4.000
2.3.0.0
CHP-GFX-DXL-xx-S
4.000
2.3.0.0
Summary of Contents for CHP Max5000
Page 2: ......
Page 12: ...x CHP Max Headend Optics Platform Chassis Controllers and Power Supplies 1508685 Rev D...
Page 100: ...4 18 CHP Max Headend Optics Platform Chassis Controllers and Power Supplies Rev D...
Page 120: ...5 20 CHP Max Headend Optics Platform Chassis Controllers and Power Supplies Rev D...
Page 199: ...Rev D System Management Module 2 SMM 2 7 33 Figure 7 28 Add CHPMax5000 Device Window...
Page 261: ...1508685 Rev D CHP Max Trap Information B 29...
Page 262: ...B 30 CHP Max Headend Optics Platform Chassis Controllers and Power Supplies 1508685 Rev D...
Page 266: ......