Rev D
CHP Max DC Power Supply
5-13
Figure 5.10
Fan 1 Current and
Fan2 Current
Threshold Limits
Updating DC Power Supply Module Microcontroller Firmware
Update the DC power supply firmware through the CHP Max
Craft Management Software
using
either of the following two methods.
Method 1
➤
To update DC power supply microcontroller firmware
1. Obtain the appropriate firmware file through ARRIS technical support or your sales
representative. Use firmware file listed in Table 5.5.
2. Ensure that the power supply module requiring the firmware download is powered
up.
3. Start the
Craft Management Software
GUI.
4. If either an SMM or CMM module is installed in the chassis with the module requiring
the firmware download, go to Step 9.
Table 5.5 CHP DC Power Supply Firmware Hex Files
Firmware Hex File Name
PSDC.hex
Note
If either an SMM-1 or CMM-1 is installed in the chassis with the power supply
module requiring the firmware download, Craft Management Software GUI version
7.0.15 or later must be used.
Summary of Contents for CHP Max5000
Page 2: ......
Page 12: ...x CHP Max Headend Optics Platform Chassis Controllers and Power Supplies 1508685 Rev D...
Page 100: ...4 18 CHP Max Headend Optics Platform Chassis Controllers and Power Supplies Rev D...
Page 120: ...5 20 CHP Max Headend Optics Platform Chassis Controllers and Power Supplies Rev D...
Page 199: ...Rev D System Management Module 2 SMM 2 7 33 Figure 7 28 Add CHPMax5000 Device Window...
Page 261: ...1508685 Rev D CHP Max Trap Information B 29...
Page 262: ...B 30 CHP Max Headend Optics Platform Chassis Controllers and Power Supplies 1508685 Rev D...
Page 266: ......