non-linearity of the focus knob that can cause a misalignment
with pre-marked focus rings and hand-marked rings that are
exchanged between various Hi-5 units.
ADVICE
Do ONLY use the service mode if you experience issues and
need to re-calibrate the Hi-5 control elements! Make sure that
you understand the calibration procedure before using it.
To access the web interface, proceed as follows:
1. Connect Hi-5 and a computer via USB-C interface.
2. Open the web browser and enter the address hi-5-xxxxx.local,
with xxxxxx being the serial number of the Hi-5.
3. Enter user name: service
4. Enter password: access
To enter the service mode, proceed as follows:
1. Go to the
Service
tab.
2. Select
Enable Service Mode
.
3. Proceed with testing and calibration as per the displayed
instructions.