 PROGRAMMABLE  POWER   SUPPLY

A R R A Y   E L E C T R O N I C   C O . , L T D

     COPYRIGHT©ARRAY   2002

Operating Manual

3645A-TYPE

Summary of Contents for 3645A-TYPE

Page 1: ...PROGRAMMABLE POWER SUPPLY A R R A Y E L E C T R O N I C C O L T D COPYRIGHT ARRAY 2002 Operating Manual 3645A TYPE...

Page 2: ...3 6 1 Set up the maximum voltage output value 0 36V 12 2 3 6 2 Set up the key sound 13 2 3 6 3 Set up the communication 13 2 3 6 4 Set up communication address 0 254 13 2 3 6 5 Set up locking key boar...

Page 3: ...safety ground at the power outlet For instruments designed to be hard wired to the AC power lines supply mains connect the protective earth terminal to a protective conductor before any other connecti...

Page 4: ...cable for RS232 Communication cable for RS485 Mounting rack 3645A Type programmable DC power supply is designed and manufactured by ARRAY Electronic Co ltd This instrument is a kind of mini size DC p...

Page 5: ...olution at 1mv 4 Protection for over or lower voltage 5 Protection for over or lower current 6 Adjustable voltage and constant voltage output 7 Adjustable current and constant current output 8 Can be...

Page 6: ...keypad Please see the following picture 1 2 3 4 1 4 2 Structure 1 4 2 1 Front view Fig2 Front view of 3645 DC power supply 1 LCD display 2 Arrangement of the Keyboard 0 00V 0 00A 0 00W ON Fig3 LCD Dis...

Page 7: ...eration The right moving key ESC Can be used to exit any working state OK Confirmation key Rotary SW The rotation key Fig5 Rotary and function keys 1 4 2 2 Back view The fuse can be changed easily by...

Page 8: ...date which had been set up 5 Recall the stored data 2 2 2 Sub functions 1 Set up maximum protection voltage 2 Turn ON OFF the sound of key 3 Set up the communication 4 Lock ON OFF the key board 5 Set...

Page 9: ...he LCD you can move the cursor to the first number second number etc by using and buttons and then rotate to change each number and let it stay at 24 3 V then confirm the value by pressing V set butto...

Page 10: ...can change the output status by using ON OFF button The button is a turn over button when the original output is ON press the button then the output will be changed to OFF status when the original out...

Page 11: ...mple set up the voltage 15V current 2A Maximum output voltage 18V key board locked Maximum output power 25W Baud rate 9600 communication address 05 after done the setup users can store all the above s...

Page 12: ...power 6 Baud rate 7 Communication address The recall operation is as following Procedure The operation Methods LCD display Step 1 Press Recall button 0 000V 0 00A 0 00W OFF Step 2 Enter the password...

Page 13: ...display the menu functions one by one user MAX OUT VOLTAGE can use the UP and DOWN button to change the KEY SOUND SET selecting each function Press Enter button to execute COMMUNICATION SET the select...

Page 14: ...ll be your password and confirm the password by pressing Enter button 2 3 6 3 Set up the communication This function is for monitoring the output data of the power supply by using a computer When you...

Page 15: ...ge to select DON T SAVE VOLT means not to save the last set up voltage value 2 3 6 6 Set up constant power output the range is from 0 to 108 W When you select the MAX POWER function the LCD will displ...

Page 16: ...lation Initial Interface 3 1 2 Then it will enter the interface as in Fig 3 2 Press NEXT to continue Fig 3 2 The Installation Interface 2 3 1 3 In Fig 1 3 there is some explanation to some products in...

Page 17: ...tinue Fig 3 5 The Installation Interface 5 3 6 In Fig 3 6 enter the file folder s name and the default name is POWERMS Generally it is not needed to enter and it is just need to click NEXT Fig 3 6 The...

Page 18: ...e initial interface as shown in Fig 3 9 Fig 3 9 The System Start Diagram 3 2 3 Wait for the end of the system initialization and then it will enter the main interface as shown in Fig 3 10 Fig 3 10 The...

Page 19: ...e only the COM port set and the POWER selection can be carried out and other function cannot be used So users must login and operate and it guarantees the security of the system Select the icon and th...

Page 20: ...rame as shown in Fig 4 4 will be displayed Fig 4 4 COM Port and address set In Fig 4 4 select the page key COM and select the COM port from the pull down table If the COM port does not exit the system...

Page 21: ...address of the power cannot be set and the prompting diagram as shown in Fig 4 7 will be displayed This time the communication cable must be checked Fig 4 7 Communication Failure Explanation For the f...

Page 22: ...mouse to the icon and then rotate the button 2 Using the keyboard Select the V button enter the data and then select the OK button There are two methods to set the voltage range one is by using the ro...

Page 23: ...l be displayed Fig 4 16 Users Manage 1 Append User Select the page key APPEND and the user type generally is General Enter the user s name cannot be blank and the password twice must be the same and t...

Page 24: ...up Fig 4 19 Deleting User Prompting Explanation Manager and Lowest are retained by the system and cannot be deleted 4 Event Select the page key EVENT and the dialogue as shown in Fig 4 20 will be dis...

Page 25: ...button and all the records agreed with the conditions will be listed 3 Set the Report Select REPORT and it will be OK 4 Print the Report Select PRINT and it will be OK 5 Query Totally Select TOTAL an...

Page 26: ...Running Diagram 3 Keyboard Explanation Number Keys 0 9 the point key C the clearing key the backspace key V the voltage setting key Unit V 0 36 000 A the current setting key Unit A 0 3 000 mV the volt...

Page 27: ...ompany and so on Select the icon and the system will automatically be in the lowest limit of authority User must login again for the operation When leaving the user must carry out the canceling operat...

Reviews: