background image

 

 

INSTALLATION AND OPERATING INSTRUCTIONS 

 

 

Astro Express 2 - Hot Water Delivery System 

 
 
 
 

TYPICAL APPLICATIONS 

 

The Armstrong Astro Express 2 hot water delivery system ensures that users have hot 
water at the tap when you need it, while helping to conserve water. It’s easy to install, 
and does not require special return piping to the water heater. 
 
Equipped with a high performance circulator and adjustable flowrate injection valve, 
the Astro Express 2 system is a “one-size-fits-all” solution for virtually any residential 
installation. The Astro Express 2 is the ideal solution for existing home retrofit where 
recirculation system return line installation is impractical, or new home construction 
where dedicated hot water return line installation is cost prohibitive.

 

 

 
 
HOW IT WORKS 

 

Armstrong Astro Express 2 hot water delivery systems consist of a circulator for water 
heater mounting, and a valve for under-sink mounting. In operation, the timer activated 
circulator creates differential pressure across the Astro Express LF valve. When the water 
at the hot water faucet cools below the Astro Express LF valve low temperature setpoint, 
the valve opens, allowing the cooled water to be injected into the cold water line. When 
the water reaches the valve high temperature setpoint, the valve closes. The valve is 
equipped with a pressure independent flowrate adjustment to maintain the desired 
temperature balance. Additionally, the valve is equipped with a check valve to prevent 
cold water backflow when the hot water faucet is opened.

 

 
 
INSTALLATION

 

 

WARNING: 

  Installation should only be completed by qualified personnel, in accordance with all applicable codes, and following 

generally accepted installation practices. 

  Ensure the hot and cold water supply is turned off before installation, to avoid personal injury or damage to 

property. 

  Read and understand these instructions thoroughly before beginning the installation. 

 

CAUTION:

 

Prior to installation flush all piping of any foreign material to prevent pump blockage and prevent damage. 

FILE NO.: 

10.817 

DATE: 

Apr. 4, 2011 

SUPERSEDES: 10.817 
DATE: 

Feb. 24, 2010 

Page 1 of 5 

Reviews: