Pool Alarm 

User G

uide

 

Summary of Contents for Pool Alarm

Page 1: ...Alarm Radio Monitoring Ltd Brunel Road Leominster Herefordshire HR6 0LX tel 01568 610 016 fax 01568 615 511 email sales arm uk com web www arm uk com Pool Alarm User Guide ...

Page 2: ......

Page 3: ... Call Points 3 3 Battery Replacement 4 Emergency Alarm Units 4 1 Call Levels 4 2 Resetting Call Points 4 3 Battery Replacement 5 User Menu 5 1 Isolate Sensor 5 2 Setting the Time 5 3 Setting the Date 5 4 Sensor Battery Signal Strength Log 5 5 Event Log 5 6 Edit Sensor Names 5 7 Patient Name n a 5 8 Staff Name 5 9 Promote Patient Call n a 6 Trouble Shooting 7 Service Maintenance Appendix A Unlockin...

Page 4: ... panel also provides a 500 event rolling memory log together with a separate 500 event saved alarm activation log The system is modular with the ability to add up to 3000 unique radio devices of varying types The system has the ability to accept an infinite number of additional remote displays all complete with 2 line 20 character backlit plain English text and integral alarm acknowledgement mutin...

Page 5: ... response the system will show for any alarm call or fault that occurs on the system In Night mode a quieter sounder is used for all Calls on the system faults will be displayed but without the sounder making a noise The Enable key position activates the buttons on the front of the display such that system parameters may be changed The Silence button does not silence the sounder in this mode but i...

Page 6: ...Assistance Fast Intermittent Emergency On Constant The panel will return to normal operation only when the unit sending the call has been reset If Sounders Flashing Beacons are fitted to the system these can be programmed to activate on various call levels or call point types 2 5 Silence Button Pressing the Silence button on any of the Display units when a Call Alarm is on the system will cause al...

Page 7: ...necessary visits Note If the reset signal is not received by the control panel it will be necessary to press the reset button again 3 3 Battery Replacement To replace the battery in the Help Call units following a Low Battery fault remove the four corner screw covers with a small flat bladed screwdriver Un screw the four screws to release the front of the unit Remove the exhausted battery and disp...

Page 8: ...n the Affray Alarm unit following a Low Battery fault remove the four corner screw covers with a small flat bladed screwdriver Un screw the four screws to release the front of the unit Remove the exhausted battery and dispose of in a safe way and replace with a new battery Replace the front cover and screw the front closed and replace the four corner screw covers The Emergency Alarm units require ...

Page 9: ...ated from System Operation Use the Selection Keys to scroll through the sensors on the system Up arrow above Enable light to navigate up through Sensor list Down arrow above TX light to navigate down through Sensor list Use the key Printer key to turn a Sensor ON or OFF Note If the sensor was in fault at the time it was isolated it will be necessary to reset the Fault message by turning the keyswi...

Page 10: ...ove TX Enable to scroll through each sensor to view the battery volts If a Printer PC is connected then the Battery Signal Strength Log for all the sensors may be printed out by pressing the key Printer key This prints Sens Sensor Number Sensor Number allocated to each Unit Batt Battery Voltage Last received Battery Volts TIME Current Time Time Count since last reception Lst Last Last Time Interva...

Page 11: ...and down through the units on the system until you reach the unit that needs changing Once you have reached the unit that you wish to change the label for press Return on the keyboard to move to the bottom line Location Label field and type the new label that you wish the unit to have press Return to save the new label If the new label is shorter than the old label use the space bar key to remove ...

Page 12: ...inished see Appendix A 5 8 Staff Name Staff Keyfobs can be personalised with the Staff s name if required default is Staff 1 Staff 2 etc Follow the same procedure as for editing Patient Keyfob names Section above the display you require is Remember to re lock the memory once finished see Appendix A Staff Keyfob sensor number Keyfob name STAFF NAME 1 STAFF 1 ...

Page 13: ... is low and its internal battery should be replaced RF Fail RF FLT Fault RF Fail RF FLT is indicated on the Control Panel against a Unit Cause The Unit has failed to communicate with the Control Panel Put the unit in question into alarm and then reset it If the alarm is NOT received or the unit does not Reset then firstly change the battery and retry If the unit still does not work properly then i...

Page 14: ...ay will show the Sensor number and its location along with the fault For information about replacing the batteries in the various units please see Battery Replacement at the end of the relevant sections For faults firstly refer to the Trouble Shooting section if the fault persists then contact your Installer Supplier Do not remove any of the Call Points Units from the site as this will cause the c...

Page 15: ...nabled the memory LED illuminates on new panels only see below When the Memory is Enabled this LED illuminates To Enable Memory a memory jumper must connect both B pins on LK1 NOTE LOCKING MEMORY To Lock Memory after programming remove the jumper from both B pins the Memory LED will turn off and park the jumper on one pin only for future use Appendix A Unlocking Memory ...