background image

1

Arjay Engineering

2851 Brighton Road

Oakville, Canada, L6H6C9

Phone: ++1 (905) 829-2418

Fax: ++1 (905) 829-4701

www.arjayeng.com

[email protected]

4500-

RMS

User Manual

Summary of Contents for 4500-RMS

Page 1: ...1 Arjay Engineering 2851 Brighton Road Oakville Canada L6H6C9 Phone 1 905 829 2418 Fax 1 905 829 4701 www arjayeng com arjay arjayeng com 4500 RMS User Manual ...

Page 2: ...dio frequency energy and if not installed and used properly that is in strict accordance with the manufacturer s instruction may cause interference to radio communications It has been type tested and found to comply with the limits for a class A computing device pursuant to subpart J of part 15 of FCC Rules which are designed to provide reasonable protection against such interference when operated...

Page 3: ... the units model number to the Model Numbering table listed below Description of Unit 4500 RMS monitors provide WebAdvantage internet based remote monitoring contolling and reporting for a wide range of analog and digital appliations Control Functions Each of these control functions are based on a 4 20mA analog input and will include user settable relay control settings along with a High and Low A...

Page 4: ...f users and property 6 The electrical installation of the controller must be performed by trained personnel only and conform to all applicable National State and Local codes 7 Operation of this product in a manner not specified by the manufacturer may result in damage to equipment or persons 8 Avoid mounting in locations that expose the controller to direct sunlight vapors vibration liquid spills ...

Page 5: ...5 Relay Card Wiring Motherboard Connections System Card Connections C N O ...

Page 6: ...6 4 20mA Input Card Wiring The 4 20mA input card requires that the external device sending the 4 20mA input signal s supply the power for the loop The external power source must not exceed 24 volts DC ...

Page 7: ...e ENTER Used to log a changed value into program HOME Used to go back to the HOME menu page CANCEL Used to cancel a pop up screen if no change is desired HELP Used to access help screens BACK Used to go back to last menu screen viewed or clear values keyed in that are not wanted The bottom right box in the RUN screen mode is a hot key that will take you directly to a particular menu screen The def...

Page 8: ...ough the sub menus to reach a point at which a value or selection is made a Pop up window will appear prompting you to enter a desired value or selection NOTE When entering new numeric values enter all available digits characters 1 Home Menu From the HOME menu select the desired menu The menu name explains what parameters can be programmed in the menu SET POINTS Setting control set points for mA i...

Page 9: ...ALARM What reading generates a Low alarm LIMIT TIMER What amount of continuous control will generate a time alarm notice The relay is locked out by this alarm DISABLER One of the digital inputs can be selected to prevent alarming Note Each alarm value can also be set up to be displayed or not on the front screen as well as remotely notified or not if connected to the Web Advantage server 2 2 Aux I...

Page 10: ...ile calibrating is the raw A D value and is only a reference A 20mA input should be around 5500 and 4mA around 1100 If the A D numbers are not in this range check input device The MAX and LOW calibration inputs are for telling the controller what to display for a 20mA input and a 4mA input For example if the input is a drum level sensor monitoring a 55 gallon drum the value for MAX should be 55 an...

Page 11: ... ten notepad items The NOTEPAD is ideal for setting up and storing into the controller s history the items typically tested for reporting a service call The Notepad items come with no names but when an individual note is selected a menu for setting it appears NAME Pick from a list of defined names or customize your own NUMBER Set the number range UNITS Set the units of measurement ALARMS Set Hi Lo...

Page 12: ...y only menu TEMP SCALE Set Celsius or Fahrenheit HISTORY Sets the history time stamp interval SYS INFO Tells unit software specifics 7 1 Password ADMIN PASSWORD The administrator password gives access to all menus except factory set up USER PASSWORD The user password allows the user to access HOME menus that are made available in USER SET UP ALARMS SYS 1 ALARMS SET DATE AND TIMES SET DATE SET TIME...

Page 13: ...ge pdf Note The Network card must be RESET after making any changes to Network setting in order to save changes and reset communications WIFI DHCP Enable or disable if available SETTINGS This menu is used to configure a variety of extended network options WIFI NETWORK This menu is used for choosing the local wifi network and setting the password This is covered more in a separate manual https www ...

Page 14: ...ry is reset 8 1 Viewing History RELAY LOGS Relay activations displayed in a log form Arrow up to advance through the log ALARM LOG Alarm activations in log form SENSOR HISTORY For selecting the parameters and viewing of a given probe reading s history in log or graph form EVENT LOG Displays various activities 8 2 Notepad Entries The Notepad section under History is where the user goes to enter new...

Page 15: ...dv3 USER ID and password _____ Yes if No proceed to page 18 Has your account admin added the device and linked it to your USER ID _____ Yes if No proceed to page 19 Congratulations You are now ready to go online with WebAdvantage https webadvantage online Complete WebAdvantage Manual ...

Page 16: ...rs for processing Setting Up a USER ID Before you can view a device a USER ID must be setup Note If you already have a USER ID and are just adding a new device skip to step 4 Step 1 Visit https webadvantage online or access the registration form with the QR code below Step 2 Choose Create Account at the bottom of the login screen Step 3 After completing form click SAVE to create ID Note The email ...

Page 17: ...Note Only company administrators can add edit remove or modify devices user accounts history reports User account permissions only allow for viewing of devices Step 2 Choose Administration at top of page Step 3 Then choose Manage Devices Step 4 Enter the device s Name and Serial Number The remaining fields are optional Click SAVE to submit Admins Only Add Device and Assign USER ID Setting Up Acces...

Page 18: ... drive in one of two fiel formats WebAd vantage or generic comma separated default To change formats see Step 2 Sample Log Data log txt files Step 1 To transfer the contents to the XS history logs ot the USB drive select History USB by using the Arrow buttons Then press ENTER Note Status will be displayed on the screen to show the percent completed of each log record type Once the log is completel...

Page 19: ...ing and multiple user internet access Contact Advantage Controls or support ad vantagecontrols com with your unit s serial number to learn more After an XS is set up for cloud storage follow these steps 1 Login to the secure web server https webadvantage online 2 Locate the controller you have data for and click Reports 3 Click History Upload on the left 4 Click Choose File and select the file you...

Page 20: ... Set tings from one XS to another This process is referred to as cloning Step 1 With the controlller powered up plug the USB drive into the XS USB port The USB DRIVE DETECTED pop up window will appear Select Config USB Config to USB by using the Arrow buttons Then press ENTER The User settings will be saved to the USB drive under the file name CONFIG BIN The pop up window will close when the copy ...

Page 21: ...trode Faulty wiring to electrode Clean electrode Replace electrode if needed Replace wiring if needed No system power Check power source Check fuse Check connections Plug into different receptacle Replace as needed Make sure ribbon cables are secure Relays not energized Check fuse Ribbon cable loose Limit time Replace as needed Reseat ribbon cable between relay and motherboards Display blank or re...

Reviews: