background image

Page | 1 

Owner’s Manual 

SlimKool

 Window Cooler

Model 

SK45AA

DO NOT 

Return to store

 

For help with installation or warranty issues call 

623-202-1395

 or

www.

arizonaaircoolers

.com

 

For parts

 

[email protected]

This product may qualify for up to $300 in rebates 

Check with your local agency 

Summary of Contents for SlimKool SK45AA

Page 1: ...SK45AA R DO NOT Return to store For help with installation or warranty issues call 623 202 1395 or www arizonaaircoolers com For parts custsomerservice arizonaaircoolers com This product may qualify for up to 300 in rebates Check with your local agency ...

Page 2: ...d cord plug or other component Do not run the power cord under carpet or other floor covering Do not use the power cord with an adaptor plug that converts the 3 pin plug into a 2 prong connector Do not use the cooler with an improperly grounded outlet Do not alter or modify this cooler Do not allow children to install operate or service this cooler WARNING To reduce the risk of fire or electric sh...

Page 3: ...essing the drain button Also the logic in the control is operating the pump after 4 hours of cooler operation It is critical to the life of the product that the drain function is not restricted in any way as this may void unit warranty and will cause damage to your filters and cooler Use the appropriate drain piping or hose to drain away the water when discharged as per your local codes and or ins...

Page 4: ...eanFreq drains away the water Operating the unit The SlimKool cooler can be operated in with Remote main power can be engaged on the control pad on the vent all other activity will need the remote to operate Now press the snowflake for cooling PUMP Press the fan speed button as shown according to COOL Mode Press the POWER button n remote unit will start The unit will now operate with the fan motor...

Page 5: ...r line connection to facuet see pg 11 Unpacking The Unit Warning When you receive your unit the fan assembly and the over flow fitting will be partially located inside the wet section of the product Fan Assembly Before installing the product in the window the telescopic section of the unit MUST be fixed in place Step 1 Pull the fan assembly out of the unit by approximately 6 150mm until it hits th...

Page 6: ...ow two or more people will be required for this so that the unit is hard up against the outside wall of the house Ensure that the unit is installed level in the vertical and horizontal positions as Ensure that the unit is installed level in the vertical and horizontal positions as illustrated prior to fixing the cooler Installation Note that if the cooler does not fit hard up against the outside w...

Reviews: