48
maintenance guide
3.2
3 WAY VALVE
3 WAY VALVE UNIT
Tools
Time
5 min
1
Unplug the diverter valve cable
Remove the clip and lift the motor from the
diverter valve body
2
Drain the boiler (see 3.3). Remove the clip and
lift the diverter valve from the assembly
When reassembling, ensure the diverter valve is
aligned correctly
3.3 DRAINING
DRAINING
Tools
Time
5 min
1
Turn the drain valve anti-clockwise to open and
drain the water from the boiler.
CLAS 24/30 FF
3 way valve
Draining