7
EN
Up to 3.5 kW
(One Phase)
0XOWLSROHVZLWFK
7HUPLQDOEORFN
7KHUPRVWDW
0LFURVZLWFK
6ZLWFKHV
/('/LJKW
+HDWLQJHOHPHQWV
3UHVVXUHVZLWFK
INSTALLATION
AURES
SLIM
)ORZ 5DWH .QRE )ORZ 'LVSOD\ PRGHO
7HPS'LVSOD'LVSOD\PRGHO
3RZHU.QRE
3RZHU/HG
Water Inler
Water Outlet
Feature
SLIM
SLIM FLOW
SLIM DISPLAY
Water Inlet
x
x
x
Water Outlet
x
x
x
3RZHU/('
x
x
x
3RZHU.QRE
x
x
x
Flow rate Knob
x
x
Temperature Display
x
Unit Dimensions: Height 183mm Width 290mm Depth 113 mm
Table 2
Power
kW Loaded
Heating Setting
Recomended
Cable Size
Recomended
Fuse Rating
220V 230V 240V
3.5kW
3.5
--
--
1.5+2.0 kW
1.5 mm
2
16 A
3.5kW
3.5
--
4.1
1.5+2.0 kW
2.5 mm
2
25 A
5.5kW
5.5
--
6.5
2.2+3.3 kW
4 mm
2
32 A
• Operating water pressure 20-800 kPa (0.2-8 bar) • Water pressure operating power switch
• Standard 1/2"Ø compression inlet connection • Top-left and right cable entry • Bottom-left water entry