O-235E | 4 - Install the Access Point | 16
Power On the AP
Plug one end of the Ethernet cable into the PoE+ switch or compatible PoE injector (a Single-port
High Power Midspan, 802.3at compliant, up to Gigabit PoE with 30W minimum power output) and
the other end into the LAN1 (PoE+) on the O-235E. Make sure the PoE+ source you are using is
turned ON.
Earthing or Grounding: The AP must be properly grounded using a copper earthing wire (12 ~ 10
AWG) and a tin-plated lug as shown in the following image. The wire and the lug must be tightened
at the earthing screw on the AP.
Note: O-235E APs are intended to be supplied with UL-listed PoE+ power source suitable for
use at 65 degree Celsius, and whose output meets LPS requirements or PS2, with a rating of 48V DC
(0.5A minimum).
The following table shows the dimension of the earthing screw and lug.
Item
1
2
3
4
5
6
7
8
Tolerance
± 0.5
± 0.5
± 0.5
± 0.5
± 0.5
± 0.2
± 0.2
± 0.2
Size
1.0
21.50
5.90
13.0
7.20
4.30
3.40
6.70