Mains filter
Only active at alternating voltage supply.
The digital input filter suppresses ripple voltage and faults on the inputs 2/3 at 50/60 Hz AC operation. The supply voltage func-
tions as reference. The filter can only be set if a 7-segment display is present. For Selection of menu item FI see bullet point 6.
FI
Switching threshold
0
OFF
1
50%
2
60%
3
70%
4
80%
5
90%
Example:
Menu status 1=50%, i.e. at a supply voltage of e.g. 230 V AC voltages below 115 V AC will not be processed at the inputs 2/3.
14.
Maintenance
14.1
Service
ARIS actuators of type Tensor have a lifetime lubrication and are generally maintenance-free.
14.2
Accessories
No special tools are required for installation.
14.3
Spare parts
Order spare parts at [email protected] any time.
Please always state the serial number of the actuator.