ARI Eliptix R-30-X Installation, Operating, Maintenance Download Page 1

R-30 X 2W .IOM.ENG01

 

 

 

 

 

 

 

 

 
 

R-30-X  

 

2W Horizontal Float Level Control Valve 

 
 

The following is a step by step narrated description of the Eliptix R-

30

-X 

2

W Horizontal Float Level 

Control Valve installation, operation and maintenance processes. 
The A.R.I. R-

30

 Series is a line of metal, diaphragm-operated, hydraulic control valves. 

The valves are suitable for installation in agriculture, water transmission and waterworks systems 
for irrigation, landscape and infrastructure applications. 
The R-

30

 series has an innovative elliptic shaped diaphragm that integrates well with a wide variety 

of regulating control pilots, solenoids and control accessories. 
They are compatibility designed for water level control, flow control, electric & remote control as 
well as pressure reducing & pressure sustaining operation.

 

The R-

30

-X 

2

W Horizontal Float Level Control valve is a hydraulic on/off control valve designed to 

maintain a preset level of water in a tank or a reservoir, according to the position of the float valve. 
Low water level causes the buoy to drop and the float valve to open; this issues a command that 
opens  the  main  valve.  Rising  level  of  water  brings  the  buoy  up,  closes  the  float  valve,  and 
commands the closure of the main valve. 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for Eliptix R-30-X

Page 1: ...lliptic shaped diaphragm that integrates well with a wide variety of regulating control pilots solenoids and control accessories They are compatibility designed for water level control flow control el...

Page 2: ...ol Valve 9 2 4 Initial Set up The ON OFF Application 10 3 OPERATION INSTRUCTIONS 11 4 MAINTENANCE 12 4 1 Periodic Inspection 12 4 2 Storing the valve 12 5 TROUBLESHOOTING 13 6 DISMANTLING AND ASSEMBLI...

Page 3: ...ever whether caused by accessing and or relying upon this Disclaimer and or in any document enclosed hereto including without limitation any links procedures or materials A R I shall NOT assume any li...

Page 4: ...iorwarning Make surethatallproducts outlet ports arenotdirectedtowardelectricalelements pumps orpeople 8 Always open and close valves slowly and gradually 9 Please note that the maximum working pressu...

Page 5: ...lations set for handling this type of fluid 3 Before disconnecting the product from the system and before releasing the residual pressure do NOT loosen or unscrew the product bolts removeanyprotection...

Page 6: ...ns 2 Make sure that all the tools ladders lifting devices etc used during the maintenance procedures are taken away from the product area and stored 3 Remove grease and fat material residues in order...

Page 7: ...2 Before installing the valve flush the pipeline to remove scale dirt and other particles that might affect the valve performance 3 Carefully remove the valve from the shipping package Unload all valv...

Page 8: ...d downstream of the control valve 8 Y Strainer upstream of the control valve 9 3 Close the outlet 2 way ball valve 2A 4 Turn on the water supply to the valve 5 Check for leaks tighten bolts fittings i...

Page 9: ...e upstream isolation valve 8 4 Check for leaks tighten bolts fittings if necessary 5 For automatic operation of the level control valve open the 2 way ball valves 2 and 2A 6 To manually close the valv...

Page 10: ...to open When the reservoir s water level raises back to the pre set level the horizontal float 5 floats with it The float valve 5C closes water from the upstream 2 way valve 2 flows into the control...

Page 11: ...the valve close the outlet 2 way ball valve 2A and make sure that the inlet 2 way ball valve 2 is open 3 To manually open the valve close the inlet 2 way ball valve 2 and make sure that the outlet 2...

Page 12: ...lly inspect the valve s diaphragm for any tears 2 Every 12 months inspect the valve s operation and clean the Finger Filter 3 Check the downstream pressure adjust if required 4 2 Storing the valve It...

Page 13: ...Inlet 2 way ball valve position 2 1 Open the 2 way Inlet ball valve 2 2 The Diaphragm is damaged 2 Check the Diaphragm s integrity 2 Turn off the water supply to the valve remove the bonnet and replac...

Page 14: ...ing at the other 24 mm spanner open at one end and ring at the other 2 Release Pressure Make sure that the water supply to the valve is switched off release any residual pressure and isolate the valve...

Page 15: ...Disassembling the valve 1 Using a 24mm spanner release the 4 bolts of the valve s bonnet in a diagonal manner A D 2 Un screw the bonnet s bolts E F and remove the bonnet from the valve s body G H 1 1...

Page 16: ...R 30 X 3 Remove the valve s spring I J 4 Remove the valve s diaphragm K L 3 3 4 4...

Page 17: ...Cleaning the Finger Filter 1 Disassemble and clean the finger filter using a 20mm spanner release the upstream 2 way manual valve A B Then using a 19mm spanner release the finger filter and clean it C...

Page 18: ...nd tightened in all directions parallel to the valve s body 6 6 Reassembling the Control loop 1 Make sure that all the control loop components are in good condition and clean 2 Clean the control tubin...

Page 19: ...R 30 X 7 DIMENSIONAL DRAWING...

Page 20: ...le nor does this warranty extended to any consequential or incidental damages or expenses of any kind or nature regardless of the nature thereof including without limitation injury to persons or prope...