12 Loop resistance measurement (R)
62
ARGUS Copper Box
12 Loop resistance measurement (R)
Loop resistance measurement enables you e.g. to detect short-circuits and estimate line
lengths, among other things.
A voltage check is performed before the measurement in which the voltage
limits given in the table (see page 11) may not be exceeded. A loop must be
created. This can be ensured using the instrument kit function "short circ.
Tip-Ring-Ground".
Loop resistance measurement is not intended for single-wire deter-
minations. Use resistance symmetry measurement for this purpose, see
page 55.
See the chapter Technical data page 14 for information on measuring ranges, resolutions
and accuracies of loop resistance measurement.
Loop resistance measurement settings
ARGUS in the status display.
The loop resistance measurement is not
yet started.
Loop resistance is always measured
continuously.
Hotkeys/settings of loop resistance mea-
surement see page 20 and in the sheet
under.
When you select the susceptibility
"Insecure (fast)", the red warning
"ATTENTION: susceptible"
appears on the display.
<Menu>
Opens the Copper Box
<Start>
Starts loop resistance
measurement.